Chapter 4
CIP Axis Attributes
236
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
Cumulative number of times AC Mains has been cycled.
Cumulative Control Power Cycles
Usage
Access
T Data
Type
Default
Min
Max
Semantics of value
Optional - BD
MSG
DINT
-
-
-
Cumulative number of times Control Power has been cycled.
See also
Interpret the Attribute Tables
These are the device status attributes associated with a Motion Control Axis. Any
status bits that are not applicable are set to 0.
CIP Axis State
Usage
Access
T Data
Type
Default
Min
Max
Semantics of Values
Required - All
Get/GSV
T USINT
-
-
-
Enumeration
0 = Unconnected
1 = Pre-Charge
2 = Stopped
3 = Starting
4 = Running
5 = Testing
6 = Stopping
7 = Aborting
8 = Faulted
9 = Start Inhibited
10 = Shutdown
11 = Axis Inhibited
12 = Not Grouped
13 = No Module
14 = Configuring
15 = Synchronizing
16 = Waiting for Group
17-255 = Reserved
Enumerated value indicating the state of the motion axis.
CIP Axis Status Attributes