Chapter 3
Interpret the Attribute Tables
168
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
ID
Access
Rule
Attribute
B
E
F
P
V
T
Conditional Implementation
473/325
Set
Velocity Limit - Positive
-
-
Y
Y
Y
-
471
Set
Velocity Lock Tolerance
-
-
N
Y
Y
-
469
Set
Velocity Low Pass Filter Bandwidth
-
-
-
Y
Y
-
790
Set
Velocity Negative Feedforward Gain
-
-
-
N
N
-
470/327
Set
Velocity Threshold
-
N
N
Y
Y
N
608
Set
Zero Speed
-
-
N
N
N
N
V24
609
Set
Zero Speed Time
-
-
N
N
N
N
V24
The following table identifies the optional attributes and corresponding control
mode functionality supported by a PowerFlex 755 drive module.
ID
Access
Attribute
B
E
F
P
V
T
Conditional Implementation
367
Get
Acceleration Fine Command
-
-
N
N
N
485
Set
Acceleration Limit
-
N
N
N
N
482
Get
Acceleration Reference
-
-
N
N
N
481
Set
Acceleration Trim
-
-
N
N
N
1376
Set
Actuator Diameter
N
N
N
N
N
DScale
1377
Set
Actuator Diameter Unit
N
N
N
N
N
DScale
1374
Set
Actuator Lead
N
N
N
N
N
DScale
1375
Set
Actuator Lead Unit
N
N
N
N
N
DScale
1373
Set
Actuator Type
N
N
N
N
N
DScale
732/267
Get
Analog Input 1
N
-
Y
Y
Y
Y
733/268
Get
Analog Input 2
N
-
Y
Y
Y
Y
734
Set
Analog Output 1
N
-
Y
Y
Y
Y
735
Set
Analog Output 2
N
-
Y
Y
Y
Y
873/2726
Set
Auto Sag Configuration
-
-
Y
Y
Y
Y
V28
874
Set
Auto Sag Slip Increment
-
-
Y
Y
Y
Y
V28
876
Set
Auto Sag Start
-
-
Y
Y
Y
Y
V28
0
Set
Axis Configuration
R
R
R
R
R
O-Enum
0 = Feedback Only (N)
1 = Frequency Control (Y)
2 = Position Loop (Y)
3 = Velocity Loop (Y)
4 = Torque Loop (Y)
PowerFlex 755 Standard Drive