2–28
Regenerative DC Bus Supply Operation
Programming
Overview
The 1336 REGEN Line Regeneration Package is designed so that
factory default parameter settings allow it to operate satisfactorily
under a wide variety of load and utility conditions.
Important: The 1336 REGEN Package has been shipped from the
factory with Parameter 1 set to the Regenerative Brake
Mode of operation. For Regenerative DC Bus Supply
applications, this parameter must be reset as described in
“Operational Mode” on page 2-29.
With the exception of Parameter 1, for the majority of applications
there should be no need to adjust parameters. Should utility or load
conditions deviate from the “normal” conditions listed in the
Specifications, the following parameters have been provided to allow
adjustments to factory settings.
Conventions
• Only parameters that are used in the Regenerative DC Bus Supply mode of
operation are listed in this chapter.
• Some parameters can be modified when the 1336 REGEN converter is
enabled. Other parameters can be modified only when the 1336 REGEN is
not enabled.
•
Parameter Names
appear in the display in the left column. If mentioned
in text, they will be shown in
[brackets]
.
• The
Parameter No.
is a unique number assigned to each of the 1336
REGEN Package parameters.
• The
Display Units
are units shown on the HIM — Bits, Amps, Volts,
Percentages or Numbers.
• The
Parameter Type
heading indicates whether or not the parameter is
read/write or read only. If read/write, whether or not it can be changed
while the converter is enabled.
• The
Factory Default
value is the value set at the factory. In most
circumstances this value should be sufficient for the application.
• The
Min/Max Value
is the lowest/highest setting for the parameter.
•
Drive Units
are internal units used to scale values properly when reading
or writing to the converter.