Specifications
B–7
DeviceNet Communications Module
The following fugure shows how the I/O image table for the
programmable controller relates to the 1336 REGEN Converter
when a Flex I/O Module is used.
Scanner
Output Mapping
(Write)
Input Mapping
(Read)
Input Mapping
(Read)
1203–Gx5
DeviceNet to SCANport
Word 0
Logic Command
Word 1
Reference
Word 2
Not Used
Word 3
Not Used
Word 4
Not Used
Word 5
Not Used
Word 6
Not Used
Word 7
Not Used
Word 8
Not Used
Word 9
Not Used
Word 0
Logic Status
Word 1
Feedback
Word 2
Not Used
Word 3
Not Used
Word 4
Not Used
Word 5
Not Used
Word 6
Not Used
Word 7
Not Used
Word 8
Not Used
Word 9
Not Used
1336 REGEN Converter
Logic Command
Bus Voltage Reference
Logic Status
Actual Bus Voltage
SCANport
PLC, SLC
or PC
Message
Buffers
Message Handler