19
Drilling door leaf for long plate (Germany)
Set the hole gage in acc. with the
corresponding operating instructions.
Insert the hole gage into the mortise lock.
Align the hole gage by means of a water level
and fasten it with a quick clamp.
Drill 7 mm hole
from both sides
.
Drill 3 holes for long plate.
The lower hole is not standardized.
Drilling door leaf for long plate (France)
Set the hole gage in acc. with the
corresponding operating instructions.
Insert the hole gage into the mortise lock.
Align the hole gage by means of a water level
and fasten it with a quick clamp.
Drill 7 mm hole
from both sides
.
Drill 2 holes for long plate.
See also
Notes on Outdoor Installation ................................................................................................. 23
Inserting the square spindle for the lever handle
Insert the square spindle into the lock follower
(pin of the spindle on the side with the PegaSys
fitting, thin wall towards the latch bolt).
Hang fitting onto the pin of the spindle and
position it against the door leaf.
Содержание PegaSys
Страница 2: ......
Страница 4: ......
Страница 7: ...Installation Instructions for PegaSys Electronic Door Fittings ...
Страница 8: ......
Страница 34: ......
Страница 35: ...Installation Instructions for PegaSys Electronic Lock Cylinders ...
Страница 36: ......
Страница 52: ......
Страница 53: ...Installation Instructions for PegaSys Electronic Locker Locks ...
Страница 54: ......
Страница 61: ...PegaSys Locker Locks 57 Locking lever type 4 6 5 mm angled ...
Страница 63: ...PegaSys Teach In or NetworkOnCard Operation Valid for all PegaSys offline components ...
Страница 64: ......
Страница 78: ......
Страница 83: ......