PegaSys Locker Locks
55
3.6.1 Low battery warning levels
When a booking is performed with a credential, the PegaSys Offline signals that the charging status of the
battery has dropped below a certain level (3-stage signaling.) Thus you are informed well in time that the
battery has to be exchanged soon.
We recommend a battery change after the second level warning.
If the battery is empty, LED signals and bookings are no longer possible.
First level:
+ (...)
§
Red LED (
approx. 1 second
)
and booking flag (only with service flag).
Second level:
+ (...)
§
Red LED (
approx. 2 seconds
) with signal tone
and booking flag.
Third level:
+ (...)
§
Red LED (
approx. 3 seconds
)
and booking flag
After the battery change or at the initial startup, the "positive" battery status is loaded (from data format 2.1)
and written to five different credentials.
If the battery is weak, the battery status is also written to credentials five times. If the PegaSys Offline
component is connected to an access control system, this system can respond to these messages.
3.7 Resetting the locker lock
If there are malfunctions in the electronic system or if you want to re-initialize the product completely, you
have to perform a reset.
To do so, you need the facility or master card (depending on the mode of operation.)
Proceed as follows:
Remove the battery (as described under "Initial operation".)
Wait a short while.
Insert the battery again, and
immediately
thereafter hold the facility/master card in the read area, until
the product acknowledges the reading procedure with a visual signal (red signal followed by two green
flashes).
Depending on the product and operating mode, other data has to be downloaded.
Ensure correct polarity!
When inserting the battery, observe the correct polarity. An incorrectly inserted battery
can damage the device.
See also
Initial operation ....................................................................................................................... 52
3.8 Cleaning
Clean the housing with an antibacterial plastic cleaner or methylated spirit.
Do not use
any cleaning agents that contain benzine or solvents.
Содержание PegaSys
Страница 2: ......
Страница 4: ......
Страница 7: ...Installation Instructions for PegaSys Electronic Door Fittings ...
Страница 8: ......
Страница 34: ......
Страница 35: ...Installation Instructions for PegaSys Electronic Lock Cylinders ...
Страница 36: ......
Страница 52: ......
Страница 53: ...Installation Instructions for PegaSys Electronic Locker Locks ...
Страница 54: ......
Страница 61: ...PegaSys Locker Locks 57 Locking lever type 4 6 5 mm angled ...
Страница 63: ...PegaSys Teach In or NetworkOnCard Operation Valid for all PegaSys offline components ...
Страница 64: ......
Страница 78: ......
Страница 83: ......