16
Electronic Door Fittings of the PegaSys Series
Preparations for installation: Checking the cylinder length
Check the cylinder length.
For PegaSys 2.1
For Office Series
§
The profile cylinder must jut out by at least 27
– 31 mm at the exterior fitting (on the left in
the illustration) and by at least 8 – 12 mm at
the interior fitting (on the right in the
illustration).
§
The maximum the cylinder may jut out is 23 mm on
the outside (on the left in the illustration), or 12 mm
on the inside (on the right in the illustration).
For Back-to-Back mounting and mounting
with inside battery case / Variant 1:
self-locking
§
For these installation types, the profile
cylinder has to jut out by 27 - 31 mm on both
sides.