KM 255 en
General
V1.0
9
Permissible media temperature
* For SIP/CIP applications, 145 °C is permissible for a short period of time (approx. 15 min) at < 2
bar.
Caution
Risk of malfunction or damage to the device!
The dosing medium must be in liquid phase!
Observe the freezing and boiling point of the dosing medium!
Caution
Risk of malfunction or damage to the device!
The resistance of the parts that come into contact with the media depends on the
media, media temperature and operating pressure. Ensure the parts that come into
contact with the media are chemically resistant to the dosing medium in operating
conditions!
Observe the manufacturer's safety instructions when handling chemicals!
Observe limitations of dosing media depending on type of pump!
1.3
Application of the Device
1.3.1
Appropriate, Acceptable and Correct Usage
The KM 255 pump, described here is suitable for dosing liquid media strictly in accor-
dance with the instructions in this manual.
Note
Pumps in explosion protected version are identified accordingly on the pump type
plate and motor type plate, and an EC Declaration of conformity is provided in
accordance with guidelines 94/9/EC, which replaces the EC Declaration of conform-
ity which is printed in this instruction manual.
!
Warning
To operate a pump which has been identified as an explosion protected pump for
the dosing of combustible liquids or for operation in potentially explosive operat-
ing sites in accordance with guideline 94/9/EC, refer to the enclosed instruction
manual “Operating an explosion protected pump” in addition to this operation
manual.
!
Warning
Other applications or the operation of pumps in ambient and operating conditions,
which are not approved, are considered improper and are not permitted. ALLDOS
Eichler GmbH accepts no liability for any damage resulting from incorrect use.
1.4
Warranty
Warranty in accordance with our general terms of sales and delivery shall only be valid if:
•
The KM 255 pump is used in accordance with the information within this operation
manual
•
The KM 255 pump is not opened or incorrectly handled
•
Repairs are only carried out by authorised and qualified personnel
•
Only original spare parts are used for repairs
Dosing head
material
Min. media
temperature
Max. media tem-
perature < 10 bar
Max. media tem-
perature < 16 bar
PVC
0 °C
40 °C
20 °C
1.4571 *
-10 °C
100 °C
100 °C
2.4610 *
-10 °C
100 °C
100 °C
PP
0 °C
40 °C
20 °C
PVDF
-10 °C
60 °C
70° C at 9 bar
20 °C
* At 70°C maximum counterpressure of 3 ba