KM 255 en
32
15.720045-V1.0
7.6
Shutdown
!
Warning
When working on the dosing head, connections or lines:
Risk of injuries! Wear the necessary protective clothing (goggles, gloves)!
Do not allow any chemicals to leak from the pump. Collect and dispose of all che-
micals correctly!
Note
If possible, rinse the dosing head before shutting down the pump, e.g.
by supplying it with water.
7.6.1
Switching Off/Uninstalling
•
Switch off the pump and disconnect it from the mains.
•
Depressurise the system.
•
Take suitable steps to ensure that the returning dosing medium is safely collected.
•
Carefully remove all lines.
•
Uninstall the pump.
7.6.2
Cleaning
•
Rinse all parts that have come into contact with the medium very carefully:
•
Lines
•
Valves
•
Dosing Head
•
Diaphragm
•
Remove any trace of chemicals from the pump housing.
7.6.3
Storage
When you store the pump:
After cleaning (see above)
•
Carefully dry all parts and reinstall the dosing head and valves
or
•
Change the valves and diaphragm.
See “Maintenance” section.
7.6.4
Disposal
When you dispose of the pump:
After cleaning (see above)
•
Dispose of the pump in accordance with the relevant regulations.