KM 255 en
Operating the Pump
V1.0
33
8
Operating the Pump
8.1
Switching On/Off
Caution
Before switching on the pump, check that it is installed correctly. See the “Installa-
tion” and “Start-Up” sections.
8.1.1
Switching On the Pump
•
Switch on the mains voltage
8.1.2
Switching Off the Pump
•
Switch off the mains voltage.
8.2
Setting the dosing capacity
8.2.1
Setting the dosing flow and locking the stroke adjustment button
1. Remove cover (1l) from stroke adjustment button (L).
2. Use a screwdriver to loosen the locking screw (21) by approximately 2 rotations.
3. Increase/
reduce
the dosing flow while the pump is running.
3.1 Slowly turn the stroke adjustment button to the left /
right
to set the desired
dosing volume.
4. Depending on the application, tighten the locking screw (21) so that the stroke adjust-
ment button can still be turned/cannot be turned any more.
5. Replace cover (1l).
Caution
Pump cannot be operated if the stroke adjustment button is fully open! Depending
on the pump adjustment, this value may already be < 100 % on the scale display
for system pressures of > 100 bar.
Open the stroke adjustment button completely and then close by approx. 10% in
order to set the dosing flow to 100 %.
8.3
Electrical servomotor (optional)
To operate the servomotor, please refer to the instructions for the servomotor.
8.4
Electronic stroke preset counter (optional)
To operate the stroke preset counter, please refer to the instructions for the stroke preset
counter.
8.5
Electrically heated dosing head (optional)
To operate the temperature controller, please refer to the instructions for the temperature
L
Stroke adjustment button
1l
Cover
2l
Locking screw
3l
Screw
4l
Scale ring
3l
2l
1l
4l
3l
L