AcqG2Q Examples
Command
Response
>set AcqG2Q = 1
AcqG2Q = 1
Command
Response
>get AcqG2Q
AcqG2Q = 1
AcqC0Cycles
9800 |
9780
|
8780
|
9640
|
9774
AcqC0Cycles takes a single integer parameter between 1 and 255. It is the
number of acquisition cycles that are performed each time the reader scans for
Class0 tags.
Note: While this attribute has a maximum value of 255 (as do the other
acquisition settings), setting them to high values can result in very long
acquisition times, which may cause the reader to appear non-responsive. For
example, setting both AcqC0Cycles and AcqC0Count to 255 causes the reader
to perform more than 65,000 acquisitions when it is directed to look for Class0
tags.
The AcqC0Cycles parameter controls the "outer loop" of the acquisition cycle,
described in the "Tag Reading Fundamentals" chapter. Its value has a significant
impact on the time the reader takes to perform each scan for tags.
NOTE: Changes made with this command will take effect immediately.
AcqC0Cycles Examples
Command
Response
>get AcqC0Cycles
AcqC0Cycles = 1
Command
Response
>set AcqC0Cycles = 2
AcqC0Cycles = 2
AcqC0Count
9800 |
9780
|
8780
|
9640
|
9774
AcqC0Count takes a single integer parameter between 1 and 255. It is the
number of reads (Global Scroll or Inventory) that are performed in each Class0
acquisition cycle.
For example, if AcqC0Count is set to 10, then ten acquisition commands are
issued during each acquisition cycle.
NOTE: Changes made with this command will take effect immediately.
AcqC0Count Examples
Command
Response
>set AcqC0Count = 10
AcqC0Count = 10
Command
Response
>get AcqC0Count
AcqC0Count = 10