C
HAPTER
4
A
LIEN
R
EADER
P
ROTOCOL
R
EADER
I
NTERFACE
G
UIDE
D
OC
. C
ONTROL
# 8101938-000 R
EV
05
59
AcqC1Cycles
9800 |
9780
|
8780
|
9640
|
9774
AcqC1Cycles is an alias for the AcqCycles command. The ALR-9800, being a
multi-protocol reader, must explicitly call out the specific air protocol to which
each acquisition parameter applies.
AcqC1Cycles Examples
Command
Response
>get AcqC1Cycles
AcqC1Cycles = 1
Command
Response
>set AcqC1Cycles = 5
AcqC1Cycles = 5
AcqEnterWakeCount
9800 | 9780 | 8780 | 9640 |
9774
AcqEnterWakeCount takes a single integer parameter between 0 and 255. It is
the number of Wake commands that are issued at the start of each Class1 /
Gen1 acquisition cycle. The default value for AcqEnterWakeCount is 3.
The Wake commands act on tags matching the current Tag Mask.
For example, if AcqEnterWakeCount is set to 10, then ten Wake commands are
issued at the start of each acquisition cycle.
If AcqEnterWakeCount is set to zero, no Wake commands are issued.
NOTE: Changes made with this command will take effect immediately.
AcqEnterWakeCount Examples
Command
Response
>set AcqEnterWakeCount = 0
AcqEnterWakeCount = 0
Command
Response
>get AcqEnterWakeCount
AcqEnterWakeCount = 0
AcqC1EnterWakeCount
9800 |
9780
|
8780
|
9640
|
9774
AcqC1EnterWakeCount is an alias for the AcqEnterWakeCount command. The
ALR-9800, being a multi-protocol reader, must explicitly call out the specific air
protocol to which each acquisition parameter applies.
AcqC1EnterWakeCount Examples
Command
Response
>get AcqC1EnterWakeCount
AcqC1EnterWakeCount = 1
Command
Response
>set AcqC1EnterWakeCount = 5
AcqC1EnterWakeCount = 5