A
LIEN
R
EADER
P
ROTOCOL
C
HAPTER
4
R
EADER
I
NTERFACE
G
UIDE
D
OC
. C
ONTROL
# 8101938-000 R
EV
05
48
Booting Alien RFID Reader
Boot> Boot Level 1 (Console Communication) : Success
Boot> Boot Level 2 (Reader Communication) : Success
Boot> Boot Level 3 (Command Set) : Success
Boot> Boot Level 4 (Tag Manager) : Memory for 1000 Tags
Boot> Boot Level 5 (Initializing Network Interface) : ...
Boot> Boot Level 6 (Network) : Success - IP Address is 10.1.60.114
Boot> Boot Level 7 (Telnet Interface) : Success - Port 23 Ready
Boot> Boot Level 8 (Network Time Service) : Success - Time Set to
2003/12/04 12:32:59
Boot> Ready
Time
9800 | 9780 | 8780 | 9640 | 9774
These commands allow the current time to be assigned to or retrieved from the
reader.
Times used by this command are always specified in local time, as
defined by the TimeZone command.
Times are always specified by the format YYYY/MM/DD hh:mm:ss.
Changes made with this command will take effect immediately.
Time Examples
Command
Response
>get Time
Time = 2002/6/3 9:23:01
Command
Response
>set Time = 2002/6/3 19:23:01
Time = 2002/6/3 19:23:01
External I/O Commands
These commands allow you to configure and retrieve data from the reader’s
external input/output pins.
ExternalInput
9800 | 9780 | 8780 | 9640 |
9774
The reader monitors four external input pins, which can subsequently be
controlled by external proximity detectors and other input devices such as
“magic-eyes” and magnetic switches. This command allows these external input
pin values to be obtained. Please refer to the Hardware Setup Guide for pinout
diagrams.
The command returns a single byte result that represents the bitmap of
the external input pin states. Bit 0 represents the state of input #1, bit 1
represents the state of input #2, etc.
The ALR-9640's input states are inverted, as compared to the other fixed
readers. This can be rectified by using the InvertExternalInput command.
Содержание ALR-8780
Страница 8: ......