On the other hand, holding the socket open places a burden on the network. For
infrequent notifications, it is advantageous to leave the NotifyKeepAliveTime
small so that the socket is opened only long enough for a single notification to be
sent out, and is then closed automatically after message delivery.
The time can range from 0 to 65535 seconds.
The default value is 30 seconds.
NotifyKeepAliveTime Examples
Command
Response
>get NotifyKeepAliveTime
NotifyKeepAliveTime (secs) = 30
Command
Response
>set NotifyKeepAliveTime = 90
NotifyKeepAliveTime (secs) = 90
MailServer
9800 | 9780 | 8780 | 9640 |
9774
The MailServer command pair allow you to define an SMTP (simple mail transfer
protocol) mail server. This mail server is used only when automatic notification is
configured (see Notify commands) and is set to use Mail as its delivery method.
MailServer Examples
Command
Response
>get MailServer
MailServer = 12.34.56.78
Command
Response
>set MailServer = 45.224.124.34
MailServer = 45.224.124.34
MailFrom
9800 | 9780 | 8780 | 9640 |
9774
The MailFrom command pair allows you to define the email address associated
with the RFID Reader. The emails sent out by the RFID Reader will have this
parameter set in the From: field of the email header.
MailFrom Examples
Command
Response
>get MailFrom
MailFrom = AlienRFIDReader
Command
Response
>set MailFrom = [email protected]
MailFrom = [email protected]
NotifyRetryCount
9800 | 9780 | 8780 | 9640 |
9774
If a network notification fails to connect to a host at the specified NotifyAddress,
the reader will attempt to resend the notification message. Rather than endlessly
retrying a failed operation (which needlessly consumes reader resources), the
reader will stop after the number of attempts reaches the NotifyRetryCount. At
this point the reader turns NotifyMode off.