C
HAPTER
4
A
LIEN
R
EADER
P
ROTOCOL
R
EADER
I
NTERFACE
G
UIDE
D
OC
. C
ONTROL
# 8101938-000 R
EV
05
61
AcqC1SleepCount
9800 |
9780
|
8780
|
9640
|
9774
AcqC1SleepCount is an alias for the AcqSleepCount command. The ALR-9800,
being a multi-protocol reader, must explicitly call out the specific air protocol to
which each acquisition parameter applies.
AcqC1SleepCount Examples
Command
Response
>get AcqC1SleepCount
AcqC1SleepCount = 1
Command
Response
>set AcqC1SleepCount = 2
AcqC1SleepCount =2
AcqExitWakeCount
9800 | 9780 | 8780 | 9640 |
9774
AcqExitWakeCount takes a single integer parameter between 0 and 255. It is the
number of Wakes that are issued at the end of all the Class1 / Gen1 acquisition
cycles. The default value for AcqExitWakeCount is 0.
For example, if AcqExitWakeCount is set to 10, then ten Wake commands are
issued after each acquisition cycle.
NOTE: Changes made with this command will take effect immediately.
AcqExitWakeCount Examples
Command
Response
>set AcqExitWakeCount = 10
AcqExitWakeCount = 10
Command
Response
>get AcqExitWakeCount
AcqExitWakeCount = 10
AcqC1ExitWakeCount
9800 |
9780
|
8780
|
9640
|
9774
AcqC1ExitWakeCount is an alias for the AcqExitWakeCount command. The
ALR-9800, being a multi-protocol reader, must explicitly call out the specific air
protocol to which each acquisition parameter applies.
AcqC1ExitWakeCount Examples
Command
Response
>get AcqC1ExitWakeCount
AcqC1EnterWakeCount = 0
Command
Response
>set AcqC1ExitWakeCount = 3
AcqC1ExitWakeCount = 3
AcqG2Cycles
9800 |
9780
|
8780
|
9640
|
9774
AcqG2Cycles takes a single integer parameter between 1 and 255. It is the
number of acquisition cycles that are performed each time the reader scans for
Class1 / Gen2 tags.
Содержание ALR-8780