background image

Manual 

TIMY2 - General 

 

 

Page 2 

 

Important Information 

General 

Before using your 

ALGE-TIMING

 device read the complete manual carefully. It is part of the device and 

contains important information about installation, safety and its intended use. This manual cannot cover 
all conceivable applications. For further information or in case of problems that are mentioned not at all 
or not sufficiently detailed, please contact your 

ALGE-TIMING

 representative. You can find contact details 

on our homepage www.alge-timing.com 

Safety 

Apart from the information of this manual all general safety and accident prevention regulations of the 
legislator must be taken into account. 
The device must only be used by trained persons. The setting-up and installation must only be executed 
according to the manufacturer’s data. 

Intended Use 

The device must only be used for its intended applications. Technical modifications and any misuse are 
prohibited because of the risks involved! 

ALGE-TIMING

 is not liable for damages that are caused by im-

proper use or incorrect operation. 

Power supply 

The stated voltage on the type plate must correspond to voltage of the power source. Check all connec-
tions and plugs before usage. Damaged connection wires must be replaced immediately by an author-
ized electrician. The device must only be connected to an electric supply that has been installed by an 
electrician according to IEC 60364-1. Never touch the mains plug with wet hands! Never touch live 
parts! 

Cleaning 

Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never 
submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose or 
high-pressure (risk of short circuits or other damage). 

Liability Limitations 

All  technical information, data and information for installation and operation correspond to the latest 
status at time of printing and are made in all conscience considering our past experience and 
knowledge. Information, pictures and description do not entitle to base any claims. The manufacturer is 
not liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical 
modifications, use of unauthorized spare parts. Translations are made in all conscience. We assume no 
liability for translation mistakes, even if the translation is carried out by us or on our behalf. 

Disposal 

If a label is placed on the device showing a crossed out dustbin on wheels (see drawing), 
the European directive 2002/96/EG applies for this device. 
Please get informed about the applicable regulations for separate collection of electrical 
and electronical waste in your country and do not dispose of the old devices as household 
waste. Correct disposal of old equipment protects the environment and humans against 
negative consequences! 

Copyright by 

ALGE-TIMING

 GmbH 

All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the copy-
right holder. 

Содержание TIMY2

Страница 1: ...Manual General Version E120525...

Страница 2: ...ician according to IEC 60364 1 Never touch the mains plug with wet hands Never touch live parts Cleaning Please clean the outside of the device only with a smooth cloth Detergents can cause damage Nev...

Страница 3: ...eneral Page 3 Control elements 1 USB interface 2 Charging socket 3 ALGE multiport 4 Connection for displayboard 5 Connection for start emitter C0 6 Connection for finish emitter C1 7 Standard ALGE pho...

Страница 4: ...2 2 Block Time 14 5 3 Diagram of Delay and Block Time 14 6 TIMY2 Update 15 6 1 Update with Cable 205 02 15 6 2 Update with USB Cable 16 7 Memory 16 8 Info Mode 17 9 GPS Synchronisation 17 10 Menu 18...

Страница 5: ...23 10 6 3 AUTO LINE FEED 23 10 6 4 START LOGO 23 10 6 5 PRINT DAYTIME 23 10 7 PROGRAM 23 10 8 Program Specific Settings 23 10 9 KEYBOARD LOCK 23 11 Technical data 24 11 1 Pin assignment 25 12 Interfac...

Страница 6: ...ces It possesses an interface for display boards an RS232 interface for commu nication with a computer an RS485 interface to establish a network of timing devices and a future proof USB interface The...

Страница 7: ...eral competitors on course Speed speed measurement Commander terminal for diverse subprograms see manual CycleStart program for track cycling with countdown and lap counter Terminal terminal for judge...

Страница 8: ...manual start impulse and to switch on the TIMY2 STOP OFF Key for manual stop impulse and to switch off the TIMY Printer Key for paper output If you press the combination and you open the printer menu...

Страница 9: ...he menu Press menu key Select DISPLAY with arrow down key Press OK key red or green Select Back Light with arrow down key Press OK key red or green The display shows ENERGY SAVE External Supply Displa...

Страница 10: ...Italian Press menu key Select GENERAL or ALLGEMEIN with arrow down key Press OK key red or green Select LANGUAGE or SPRACHE with arrow down key Press OK key red or green The display shows Display in...

Страница 11: ...se it returns to the program Method 2 Press 2nd and STOP OFF keys Display shows Really switch off Press the red OK button If you press the red OK key within 10 seconds the TIMY2 switches off otherwise...

Страница 12: ...d NiMH battery pack NM TIMY2 The NiMH rechargeable battery pack is recommended for every TIMY2 These newly developed batteries dispose of an enormous persistance even at very low temperatures and can...

Страница 13: ...with cable 000 xx or 004 xx to other timing devices switch on the TIMY2 clear or retain memory retain time and date or correct it and confirm or trigger with START key or via channel C0 4 1 Synchroni...

Страница 14: ...rt channel C0 1 0s stop channel C1 to C9 0 3s 5 2 2 Block Time The block time is the theoretic minimum interval between two valid impulses of the same channel Impulses within the block time are saved...

Страница 15: ...ces software Flash Technology if not installed yet download Install Manager open Install Manager and connect TIMY2 with cable 205 02 to the computer click on firmware RS232 in the Install Manager the...

Страница 16: ...USB driver can be found at Download PC software Various Software Timy USB and Timy2 update start the Install Manager and click on TIMY2 USB choose method of update details can be found at Manual Timy...

Страница 17: ...TIMY2 After this the TIMY2 runs with its own precision quartz and the GPS can be disconnected The GPS Mouse can now be used to syn chronise further devices Instead of the day time setting the display...

Страница 18: ...0 1 1 ALL Prints an overall ranking of different saved times According to each program the following options are available RUNTIME ranking sorted according to run time TOTALTIME ranking sorted accordi...

Страница 19: ...rent types of automatic start number continuation for the competitors at start and finish 10 2 3 1 START Controls the start number continuation for competitors at the start MANUALLY UP DOWN 10 2 3 2 F...

Страница 20: ...ny time in this menu again 10 3 CHANNELS Configuration of the timing channels 10 3 1 INTERNAL 10 3 1 1 DELAY TIME The delay time of the internal timing channels c0 c1 c2 c3 c4 c5 c6 c7 and c8 can be s...

Страница 21: ...ry setting OFF 10 4 2 DELAYTIME 1 The delay time determines for how long the intermediate times are shown on display and scoreboard The display time can be set e g for intermediate times of the runnin...

Страница 22: ...s to time of day ADRESS address for LED display board SAFETY CAR display mode permanent or flashing LAPS number of laps CTD LAP manual or automatic FORMAT output of time of day or play time 10 5 2 RS...

Страница 23: ...10 6 3 AUTO LINE FEED 0 0 is standard enter 0 9 10 6 4 START LOGO OFF ON standard 10 6 5 PRINT DAYTIME OFF ON standard 10 7 PROGRAM To change to another program ATTENTION When changing the program al...

Страница 24: ...sh input 6 banana plug pair display board 4 D sub 25 pin 3 9 timing channels RS 232 PC connection display board RS 485 network power supply 8 24 VDC in 7 5 23 5 VDC out USB 1 power supply 8 24 V DC in...

Страница 25: ...4 c3 timing channel 3 precision 1 10 000 s 5 c7 timing channel 7 precision 1 100 s 6 data output for display board 7 RS485B 8 RS485A 9 clock for terminals CLK 10 RS232 TX 11 RS232 RX 12 common ground...

Страница 26: ...4 Banana plugs for start channel C0 5 Banana plugs for stop channel C1 6 Photocell socket 7 Pin assignment 1 c0 start channel 2 c1 stop channel 3 GND common ground 4 Ua power supply out 8 22 VDC 5 5V...

Страница 27: ...ASCII yNNNNxCCCxHH MM SS zhtqxGGRRRR CR y first sign is blank or info see below x blank NNNN start number max 4 digit prezeros arel not shown CCC channels of timing device c0 channel 0 start channel c...

Страница 28: ...Manual TIMY2 General Page 28...

Страница 29: ...Manual TIMY2 General Page 29...

Страница 30: ...RR CR Channel C2 1 intermediate time NNNBxxxxHH MM SS zhtRR CR Channel C3 2 intermediate time NNNExxxxHH MM SS zhtRR CR Channel C4 3 intermediate time NNNFxxxxHH MM SS zhtRR CR Channel C5 4 intermedia...

Страница 31: ...Manual TIMY2 General Page 31...

Страница 32: ...Manual TIMY2 General Page 32 Subject to changes Copyright by ALGE TIMING GmbH Rotkreuzstr 39 6890 Lustenau Austria www alge timing com...

Отзывы: