Manual
TIMY2 - General
Page 30
12.2 RS485 Interface
This interface is only used for special applications such as wind speed measurement, TIMY2
Terminal etc.
12.3 Interface for displayboard
Output format:
1 start-bit, 8 data-bit, no parity-bit, 1 stop-bit
Bit rate:
factory setting: 2400 baud (neccessary for
ALGE
GAZ displayboard)
2400, 4800, 9600, 19200, 28800, 38400
Transmission protocol:
ASCII
NNN.xxxxxxxxM:SSxxxx(CR)
............... Running time (without 1/10 seconds)
NNN.xxxxHH:MM:SSxxxx(CR)
............... Running time (without 1/10 seconds)
NNN.xxxxHH:MM:SS.zxx(CR)
............... Running time (with 1/10 seconds)
NNNCxxxxHH:MM:SS.zhtRR(CR)
........... Channel C1
finish time with rank
NNNCxxxxHH:MM:SS.zhtxx(CR
) ........... Channel C1 finish time without rank
NNNDxxxxHH:MM:SS.zhtRR(CR
) ........... Channel C1
total time with rank
NNNDxxxxHH:MM:SS.zhtxx(CR)
........... Channel C1 total time without rank
NNNAxxxxHH:MM:SS.zhtRR(CR)
........... Channel C2
1. intermediate time
NNNBxxxxHH:MM:SS.zhtRR(CR)
........... Channel C3
2. intermediate time
NNNExxxxHH:MM:SS.zhtRR(CR)
........... Channel C4
3. intermediate time
NNNFxxxxHH:MM:SS.zhtRR(CR)
........... Channel C5
4. intermediate time
NNNGxxxxHH:MM:SS.zhtRR(CR)
........... Channel C6
5. intermediate time
NNNHxxxxHH:MM:SS.zhtRR(CR)
........... Channel C7
6. intermediate time
NNNIxxxxHH:MM:SS.zhtRR(CR)
........... Channel C8
7. intermediate time
NNNSxxx©xxxxsxss.ssxRR(CR)
........... Speed
NNN ....................... Start number (hundreds, tens, ones - digit 1 to 3)
.
............................ a point on the fourth digit is the identification for a running time
HH:MM:SS.zht ....... time in hours, minutes, seconds and 1/1000 seconds
© ............................ speed measurement: output of following ASCII signs: 01 hex for km/h, 02
hex for m/s, 03 hex for mph
RR .......................... rank
x ............................. blank
(CR) ....................... carriage return
13 USB Interface
Currently possible applications for USB interface:
•
update the TIMY2 software with installation manager or TIMY2 USB program
•
query and change of settings (as RS232)
•
recording of times with program ComtoFile
•
evaluation with program Time.NET
•
evaluation with program Excel Writer
Содержание TIMY2
Страница 1: ...Manual General Version E120525...
Страница 28: ...Manual TIMY2 General Page 28...
Страница 29: ...Manual TIMY2 General Page 29...
Страница 31: ...Manual TIMY2 General Page 31...