8 Inspection & Maintenance
8.9
Disassembly and Reassembly of the Contherm™
This section provides the detailed procedures for disassembling and reassembling a vertically mounted Contherm
™
. Table 8-25
identifies the disassembly/reassembly procedures that are contained in this section.
Table 8-25. Contherm
™
Disassembly and Reassembly Procedures
Section
Description
8.9.1
Disassembly of the Contherm
™
8.9.2
Reassembly of the Contherm
™
8.9.3
Disassembly of the Contherms
™
Hydraulic Lift Cylinder
Note: When removing parts or assemblies from the Contherm
™
, place and arrange them systematically on a wooden skid
or other protective surface.
WARNING
Refer to chapter 2, Safety, and section 8.1
Introduction and safety before proceeding to
disassemble the Contherm
™
equipment.
8.9.1 Disassembly of the Contherm
™
The procedure for the disassembly of the Contherm
™
is provided in Table 8-26.
Table 8-26. Disassembly of The Contherm
™
Steps
Action
1
Disconnect the Contherms
™
power supply to the drive motor and disengage any related drive couplings.
2
Drain the heat exchange cylinder. Ensure there are no remaining fluids or pressure within the pipework.
3
Remove any connecting product piping from the unit.
4
Shut off and disconnect all the media supply and return lines from the Contherm
™
. Ensure there are no remaining
fluids or pressure within the pipework before dismantling.
5
Use the hydraulic rotor lift system to lower the rotor assembly. Remove the blades and rotor to a safe location.
Note: Refer to Table 7-4, Operating the Hydraulic Rotor Lift System, for its detailed operating procedure.
6
Return the hydraulic rotor lift beam to its operating position. Secure the lower head in position with clamp.
7
Disconnect the lower hydraulic tube from the lift cylinder, and drain the fluid. Manually extend the piston rod to drain the
remaining oil from the lift cylinder.
93
Содержание Contherm 6X11
Страница 2: ......
Страница 10: ...2 Safety Summary Figure 2 1B Safety Warnings Refer to section 2 3 for safety and inspection symbols 10...
Страница 52: ...7 Operations Figure 7 2A Installing the Rotor Helper Plate Figure 7 2A Installing the Rotor Helper Plate 52...
Страница 66: ...8 Inspection Maintenance Figure 8 2 Component List Figure 8 2 66...
Страница 88: ...8 Inspection Maintenance Figure 8 13 Upper Bearings Direct Coupled Electric Drive Motor 88...
Страница 99: ...8 Inspection Maintenance Figure 8 18B CONTHERM Hydraulic Lift Assembly With Hold Down 99...
Страница 117: ...10 Appendix A Additional Installation Drawings 117...
Страница 118: ...10 Appendix A Additional Installation Drawings 10 Install the hydraulic lift pump and stack valve components 118...
Страница 123: ...123...