7 Operations
Table 7-12. Recommended Cleaning Program for The Contherm
™
Cleaning Agents Temp.
Time
Chemical
Concentration
(Conc.)
Solution pH
Purpose
Water Rinse
60-120
°
F
16-49
°
C
5 - 10 minutes; until
discharge is clear
Not Applicable
Not Applicable
To remove loose soil
Caustic Alkaline
Cleaner
(Chlorine)
Additive
160-190
°
F
71 C-88
°
C
Match Product
Temperature
30 - 60 minutes
0.5 to 2% NAOH
200 ppm
Chlorine
12 - 13
To remove fat
deposits & remaining
soil
Water Rinse
60-120
°
F
16-49
°
C
Until discharge
indicates pH of 7.0
Not Applicable
Available Water
Supply
Remove and
Neutralize Alkaline
Cleaner
Acid Cleaner
(Phosphoric)
135-145
°
F;
max. 165
°
F
57-6
°
3 C;
max. 74
°
C
10 - 20 minutes
Up to 1%
3.5 - 4
Remove protein
deposits & any
remaining Alkaline
& Minerals
Water Rinse
68
°
F max. 20
°
C
Until discharge
indicates pH of 7.0
Not Applicable
Available Water
Supply
Neutralize acid
cleaner
Sanitize
68
°
F 20
°
C
0.5 - 2 minutes
Depends on sanitizer
used
Depends on sanitizer
used
Sanitize surface
Notes:
1. The recommended CIP flow rate range is 120 – 150 gpm (27 – 34 m3/hr). Optimal CIP flow rate will vary depending upon
the product solids and degree of fouling. The above flow rate range is a recommendation that should be suitable for most
products. The flow rate should be increased or decreased through trial and error to optimize cleaning flow rate, cleaning
time and chemical concentration.
2. Certain soils of products with a pH range of 3 - 4 may require less cleaning time or lower cleaning temperatures.
3. Soils of products with pH values higher than the 3 - 4 range, and which precipitate out because of high temperatures
encountered during processing, will require maximum cleaning time and temperatures.
4. You can improve the cleaning for stringy or particulate products by periodically pulsing the Contherm
™
rotor, reversing the
rotation of the rotor during the cleaning cycle and reversing the CIP flow direction for very difficult to clean products.
59
Содержание Contherm 6X11
Страница 2: ......
Страница 10: ...2 Safety Summary Figure 2 1B Safety Warnings Refer to section 2 3 for safety and inspection symbols 10...
Страница 52: ...7 Operations Figure 7 2A Installing the Rotor Helper Plate Figure 7 2A Installing the Rotor Helper Plate 52...
Страница 66: ...8 Inspection Maintenance Figure 8 2 Component List Figure 8 2 66...
Страница 88: ...8 Inspection Maintenance Figure 8 13 Upper Bearings Direct Coupled Electric Drive Motor 88...
Страница 99: ...8 Inspection Maintenance Figure 8 18B CONTHERM Hydraulic Lift Assembly With Hold Down 99...
Страница 117: ...10 Appendix A Additional Installation Drawings 117...
Страница 118: ...10 Appendix A Additional Installation Drawings 10 Install the hydraulic lift pump and stack valve components 118...
Страница 123: ...123...