8 Inspection & Maintenance
8.4.2 Flushed Standard and Flushed Hard Face Rotary Seals
The Flushed Rotary Seal is used for applications that require additional lubrication or aseptic sealing. It provides the same rotary
sealing action as the standard rotary seal, but with one additional feature -- it lubricates, cleans or sterilizes the non-product side
of the seal. Flexible hoses are provided for flushing media. Supply each seal with either potable water (lubrication) or steam
(aseptic sterilization) at approximately 15 PSIG (1 Bar). Do not exceed 1 Bar. The product pressure in the Contherm
™
must
always remain higher than the pressure of the seal flushing media so seal flush fluid will not enter the product zone.
The Flushed Hard Face Seal Assembly uses the Hard Face Seal Assembly in combination with a second seal. The secondary
seal face can be of the standard carbon or hard face material.
The inspection, maintenance, testing and replacement procedures for the Flushed Standard and Flushed Hard Face Seal
Assemblies are identical to those performed for the Standard Rotary and Hard Face Seals.
Figure 8-3 identify the assemblies and components of the Flushed Standard and Flushed Hard Face Seal Assemblies.
Table 8-5 components of the Flushed Standard and Flushed Hard Face Seal Assemblies in Contherms
™
equipped with
tangential product heads.
Table 8-5. Assemblies and Components of Flushed Standard and Flushed Hard Face Seal Assemblies
Item
Assembly/Component
1
Cap Screws
2
Outer Stationary Seal Face
3
Bushing Cap O-Ring
4
Flushed Seal Bushing
5
Quick Disconnect Nipple
6
Seal Bushing O-Ring
7
Set Screw
8
1.5 inch Seal Face
9
1.5 inch Seal Shell O-Ring
10
1.5 inch Seal Shell
11
1.5 inch Seal Spring
12
2 inch Seal Face
13
2 inch Seal Shell O-Ring
14
2 inch Seal Shell
15
2 inch Seal Spring
16
Quick Disconnect
17
Seal Flush Hose
As shown in Figure 8-3, the Flushed Standard and Flushed Hard Face Seal Assemblies utilize the same assemblies and
components for both the upper and lower product heads of the Contherm
™
.
67
Содержание Contherm 6X11
Страница 2: ......
Страница 10: ...2 Safety Summary Figure 2 1B Safety Warnings Refer to section 2 3 for safety and inspection symbols 10...
Страница 52: ...7 Operations Figure 7 2A Installing the Rotor Helper Plate Figure 7 2A Installing the Rotor Helper Plate 52...
Страница 66: ...8 Inspection Maintenance Figure 8 2 Component List Figure 8 2 66...
Страница 88: ...8 Inspection Maintenance Figure 8 13 Upper Bearings Direct Coupled Electric Drive Motor 88...
Страница 99: ...8 Inspection Maintenance Figure 8 18B CONTHERM Hydraulic Lift Assembly With Hold Down 99...
Страница 117: ...10 Appendix A Additional Installation Drawings 117...
Страница 118: ...10 Appendix A Additional Installation Drawings 10 Install the hydraulic lift pump and stack valve components 118...
Страница 123: ...123...