6 Installation
6.11
Installing a Liquid Heating or Cooling Media System
The Contherm
™
operates most efficiently with counter-current flow between the product and the media. Product enters the
cylinder at the bottom or non-driven end while liquid media enters the top or drive end. It is extremely important that pumps,
pipe lines and valves be sized and installed properly to ensure that the flow rate of the media reaches a turbulent level. Water
media must achieve a minimum of 50 gpm (190 liter/min) and non-water media (i.e. propylene glycol) must achieve a minimum
of 65 gpm (250 liter/min).
Your installation may vary from what is shown in Figure 6-20. If more than one Contherm
™
is utilized, liquid media can be piped
in parallel where each Contherm
™
is receiving its own media stream or in series flow as shown. Parallel flow must be sufficient
to maintain the above stated media flow rates in each Contherm
™
. Temperature sensors are important tools that should be
incorporated within your Contherm
™
cooling system to monitor system performance and aid in troubleshooting activities.
Figure 6-23. Component Description
The following components are typical of those used in standard Contherm
™
Liquid media heating or cooling Water/Brine
media recirculation packages:
1. Supply line solenoid valve and thermometer.
2. Centrifugal pump.
3. Check valve.
4. Flow metering valve.
5. Return line remote actuated control valve.
1
Contherm
™
Product inlet
2
Contherm
™
Product outlet
3
Heating or cooling liquid inlet
4
Heating or cooling liquid outlet
5
Supply line on/off solenoid
6
Centrifugal pump
7
Flow metering valve
8
Check valve
9
Return line remote actuated control valve
It is the end-user’s responsibility to consult a trained expert in the design of a liquid heating or cooling system for your specific
application and installation needs
Figure 6-23
46
Содержание Contherm 6X11
Страница 2: ......
Страница 10: ...2 Safety Summary Figure 2 1B Safety Warnings Refer to section 2 3 for safety and inspection symbols 10...
Страница 52: ...7 Operations Figure 7 2A Installing the Rotor Helper Plate Figure 7 2A Installing the Rotor Helper Plate 52...
Страница 66: ...8 Inspection Maintenance Figure 8 2 Component List Figure 8 2 66...
Страница 88: ...8 Inspection Maintenance Figure 8 13 Upper Bearings Direct Coupled Electric Drive Motor 88...
Страница 99: ...8 Inspection Maintenance Figure 8 18B CONTHERM Hydraulic Lift Assembly With Hold Down 99...
Страница 117: ...10 Appendix A Additional Installation Drawings 117...
Страница 118: ...10 Appendix A Additional Installation Drawings 10 Install the hydraulic lift pump and stack valve components 118...
Страница 123: ...123...