6 Installation
Contherm
™
HEAD ORIENTATION and Equipment Drainability in Horizontal Installations
To maintain a dry bearing area, the Contherm
™
head and port orientation should be kept in the configuration as demonstrated in
your project specific general arrangement drawing otherwise pooling of product, CIP solution or moisture can occur causing
premature bearing failure.
Figure 6-11. Head Port Location
1
Drive end (see below image of head orientation at outlet of Contherm
™
).
2
Outboard end (see below image of head orientation at inlet of Contherm
™
).
3
Adjustable leveling feet.
4
Pitch drive end up 0.5° toward outboard end for drainage using leveling feet.
Figure 6-13.
Head Port Location
37