5 Maintenance
Service the valve regularly.
Study the instructions carefully and pay special attention to the warnings!
Always use Alfa Laval genuine spare parts. Always keep spare rubber seals, lip seals and diaphagms in stock.
Check the valve for smooth operation after servicing.
Step 9
Mount upper valve body onto the plug/seat.
2321-0141
UP
Step 10
Assemble spindle and plug. Be sure that the disc is placed
correctly on the plug while screwing spindle and plug together.
Remember to mount the leakage fitting in the bonnet!
2321-0142