5 Maintenance
Service the valve regularly.
Study the instructions carefully and pay special attention to the warnings!
Always use Alfa Laval genuine spare parts. Always keep spare rubber seals, lip seals and diaphagms in stock.
Check the valve for smooth operation after servicing.
5.9
Changing pneumatic movement on fully maintainable actuator (NC/NO)
If the actuator is marked with a danger warning, do NOT attempt to cut the actuator open.
DO NOT DISASSEMBLE
kg
!
SPRING UNDER LOAD
Do not attempt to cut open
kg
!
Do NOT attempt to disassemble the actuator due to spring
under load danger!
Do NOT attempt to cut the actuator open due to spring
under load danger!
Before dismantling check that the actuator not is marked with a warning.
1. Rotate cylinder.
2. Remove lock wire and pull away cylinder.
3. Reverse piston and spring assembly.
4. Reverse adapter, air fitting and plug to opposite end.
5. Reassemble in reverse order (3 to 1).
A. = Pneumatic movement - upwards (NC)
B. = Pneumatic movement - downwards (NO)
2321-0150
A
B
60
Содержание Aseptic Mixproof Series
Страница 1: ...2321 0035 100000827 EN2 2019 07 Original manual Instruction Manual Aseptic Mixproof Valve...
Страница 2: ......
Страница 77: ...77...