5 Maintenance
Service the valve regularly.
Study the instructions carefully and pay special attention to the warnings!
Always use Alfa Laval genuine spare parts. Always keep spare rubber seals, lip seals and diaphagms in stock.
Check the valve for smooth operation after servicing.
Drawing 1
Drawing 2
A
B
2321-0121
A
B
2321-0122
Drawing 3
Drawing 4
2321-0124
1
A
B
2321-0123
1
It is important to place the
screwdriver underneath the plug.
42
Содержание Aseptic Mixproof Series
Страница 1: ...2321 0035 100000827 EN2 2019 07 Original manual Instruction Manual Aseptic Mixproof Valve...
Страница 2: ......
Страница 77: ...77...