5 Maintenance
Service the valve regularly.
Study the instructions carefully and pay special attention to the warnings!
Always use Alfa Laval genuine spare parts. Always keep spare rubber seals, lip seals and diaphagms in stock.
Check the valve for smooth operation after servicing.
Step 3
Remove the bonnet
2321-0094
Step 4
Loosen the plug from the spindle by using two 17 spanners
If necessary can the bushing (24) in the bonnet be changed
Clean all parts and replace diaphragm and plug seal
2321-0095
2321-0096