Wrong STM-1 interface extension board present
...................................................................................................................................................................................................................................
Alarm identifier
STM1XcWUP
Information
An STM-1 interface extension board is provisioned, but an extension board of
a different type is present, or the present extension board cannot be identified.
A proper downloading of the software will not be possible.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
The red “Fault” LED is lit.
Cause
Wrong extension board inserted, or the inserted extension board is defective.
Actions
Insert an STM-1 interface extension board, or change the provisioning.
Alarm messages
...................................................................................................................................................................................................................................
1-318
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007
Содержание 1643 AM
Страница 346: ......