Wrong 34 Mbit/s extension board present
...................................................................................................................................................................................................................................
Alarm identifier
E31XcWUP
Information
A 34 Mbit/s extension board is configured, but an extension board of a
different type is present, or the present extension board cannot be identified.
A proper downloading of the software will not be possible.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
The red fault LED on the unit is lit.
Cause
Wrong extension board inserted, or the inserted extension board is defective.
Actions
Insert a 34 Mbit/s extension board, or change the provisioning.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-313