STM-1 MS Protection switching protocol failure
...................................................................................................................................................................................................................................
Alarm identifier
MS1cFOP
Information
STM-1 multiplex section automatic protection switching (APS) protocol failure.
Alarm category
Processing error
ASAP
sdhMSP
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
The red fault LED is lit.
Cause
Unstable APS protocol.
Actions
Check that the MSP group is correctly created at both ends of the line (both
ends provisioned with the same MSP configuration).
Check that interworking between the two MSP groups is possible.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-181