Remote Power Supply Overload Detected
...................................................................................................................................................................................................................................
Alarm identifier
RPScOVERL
Information
The remote power supply box connected to the SRU is subjected to a load
greater than its capacity.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
–
Cause
This can be caused by short circuit or incorrect installation or by misuse such
as running high-powered equipment on a low-power extension cable.
Actions
Incorporate suitable overload protection devices to prevent damage. Fuses and
circuit breakers are commonly used for this purpose.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-125