STM-1 MS Moderate block error rate
...................................................................................................................................................................................................................................
Alarm identifier
MS1cDEG
Information
The block error rate of the STM-1 receive signal (optical or electrical) exceeds
a provisionable threshold.
Alarm category
Transmission
ASAP
sdhMS
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
–
Cause
Fault(s) in upstream external cabling or equipment.
Actions
Check optical connectors and/or the external cabling and equipment.
Note(s)
The signal degrade threshold can be provisioned by using the management
system.