2 Mbit/s extension board removed
...................................................................................................................................................................................................................................
Alarm identifier
E12XcUNI
Information
The 2 Mbit/s extension board is missing.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
The red “Fault” LED is lit.
Cause
Although the 1643 AM/1643 AMS is provisioned to be equipped with a 2
Mbit/s extension board, no 2 Mbit/s extension board is present.
Actions
Install a 2 Mbit/s extension board, or change the provisioning.
Alarm messages
...................................................................................................................................................................................................................................
1-28
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007