VC-11 Unequipped
...................................................................................................................................................................................................................................
Alarm identifier
VC11cUNEQ
Information
VC-11 in STM-N signal not in use.
Alarm category
Transmission
ASAP
sdhLOPath
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
–
Cause
Cross-connections not consistently defined at both sides (for example, at local
and remote station) of a line section.
Actions
Define or change the cross-connections at the other side consistently with the
local side.
Note(s)
When defining or changing cross-connections this alarm will almost inevitably
come up as it is practically impossible to issue the changes at both sides
exactly at the same time.
Alarm messages
...................................................................................................................................................................................................................................
1-224
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007