background image

DATA MULTIPLEXER 

DM1210N

 

Operation and Installation Manual

 

© Pacific Micro Systems

Summary of Contents for DM1210N

Page 1: ...DATA MULTIPLEXER DM1210N Operation and Installation Manual Pacific Micro Systems ...

Page 2: ... Systems shall be limited to the repair or replacement only In no event shall Pacific Micro Systems be liable for any special collateral incidental or consequential damages for 1 breach of any provisions hereof including without limitation provisions regarding warranties guarantees and or indemnities or 2 any claims by the purchaser concerning the goods without limitation claims of loss of goodwil...

Page 3: ...ION 3 DMxxConfig EXE DM1210N CONFIGURATION 3 SPECIFICATIONS 4 CONNECTION DETAILS 5 SOFTWARE UPGRADES 8 Designed and manufactured by Pacific Micro Systems Telephone 64 4 475 9004 136 Curtis Street Facsimile 64 4 475 9084 PO Box 9285 Mobile 64 25 449 061 Wellington 6012 Email trevor pacmicro com NEW ZEALAND Internet www pacmicro com ...

Page 4: ...sfer capabilities between all Inputs Outputs allowing flexible data combining Filtering of NMEA 0183 data thru any input or output ie All GGA VTG ZDA etc NMEA0183 or Furuno CIF sentences can be generated from trigger and depth pulses with selectable NMEA0183 depth sentence ie SDDBT SDDBS etc Output in Meters Fathoms or Feet depth output with selectable sound velocity factors between 1450 and 1550 ...

Page 5: ...rossover between the DM1210N Network port and the network port on the target PC or a straight thru cable to a hub that the PC is also plugged in to 4 Run the supply cable to a suitable 11 35v supply Red Black volts Black volts Note The DM1210N has DC isolation between its power supply input and ground This makes it suitable for interfacing to any computer installation and all isolated ground equip...

Page 6: ...h the Configuration program DMxxConfig exe Connect the DM1210N Network port to the PC network port via a cross over cable or standard cable and network hub and launch the program DMxxConfig EXE Click on the button Search for DM1210N s All DM1210N s on the network will be listed in the list box Highlight the DM1210N Serial Number and IP Address of the DM1210N to configure Click on the Get Config me...

Page 7: ... CIF Transmitted Data NMEA0183 4800 8 data bits no parity 1 stop bit CIF 4800 7 data bits even parity 2 stop bits User 50 115200 5 8 data bits None Odd Even parity 1 or 2 stop bits Digital In 0 5v Digital Out Current sink 100mA External supply required 50v max Power Requirements 11 35 vdc 50 200 mA DC isolation between power supply input and ground is provided Weight 620 grams Dimensions 170 x 150...

Page 8: ...op Input RX3 Signal 6 Current Loop Input RX3 Return J 3 Description 1 Current Loop Input RX4 Signal 2 Current Loop Input RX4 Return 3 Current Loop Input RX5 Signal 4 Current Loop Input RX5 Return 5 Current Loop Input RX6 Signal 6 Current Loop Input RX6 Return J 4 Description 1 Current Loop Input RX7 Signal 2 Current Loop Input RX7 Return 3 Current Loop Input RX8 Signal 4 Current Loop Input RX8 Ret...

Page 9: ...t Loop Input RX11 Return 5 Current Loop Input RX12 Signal 6 Current Loop Input RX12 Return J 6 Description 1 Ground 2 Ground 3 Ground 4 Ground 5 Ground 6 Ground J 7 Description 1 RS422 Output TX1 2 RS422 Output TX1 3 Ground 4 Ground 5 RS422 Output TX2 6 RS422 Output TX2 J 8 Description 1 RS422 Output TX3 2 RS422 Output TX3 3 Ground 4 Ground 5 RS422 Output TX4 6 RS422 Output TX4 ...

Page 10: ...ound 4 Ground 5 RS422 Output TX6 6 RS422 Output TX6 J 10 Description 1 RS232 Output TX7 2 RS232 Output TX8 3 Ground 4 Ground 5 RS232 Output TX9 6 RS232 Output TX10 J 11 Description 1 Digital In Out 1 2 Digital In Out 2 3 Ground 4 Ground 5 Digital In Out 3 6 Digital In Out 4 RS422 DATA OUTPUT POLARITY 5v RS422 TX ov ...

Page 11: ...ing the internal open collector transistor max sink current is 100mA SOFTWARE UPGRADES Upgrading DM1210N Software Connect the DM1210N to the PC via the Network connector Run DMxxConfig exe Click Search for DM1210N s Selected the DM1210N to upgrade from the list box Click on Utilities Select Upgrade Software Select the upgrade file to upload to the DM1210N Click Go to upload the file ...