background image

MAGIC DABMUX 

plus

 

DAB/DAB+ Ensemble Multiplexer

 

 

Hardware Manual 

 

Summary of Contents for 804310

Page 1: ...MAGIC DABMUX plus DAB DAB Ensemble Multiplexer Hardware Manual ...

Page 2: ...PAGE 2 ...

Page 3: ...k 91 90411 Nuernberg Germany Phone 49 911 5271 0 Telefax 49 911 5271 100 AVT Audio Video Technologies GmbH All Rights reserved Reproduction in whole or in parts is prohibited without the written consent of AVT GmbH Subject to changes Release date January 20 Version 2 0 ...

Page 4: ...PAGE 4 ...

Page 5: ...2 2 4 3 Rotary Knob 13 2 4 4 Keypad 13 2 5 Wiring of the system 14 3 The web interface of MAGIC DABMUX plus 15 4 Interfaces 17 4 1 LAN1 LAN 3 Interfaces 17 4 2 USB Interfaces 17 4 3 SD Card Slot 18 4 4 External 12V Power Supply Input 18 5 Optional Modules 19 5 1 ETI Module 19 5 2 Dual LAN Interface Module 20 6 Technical Data 21 7 General 23 7 1 Scope of delivery 23 7 2 Order numbers 23 7 3 Softwar...

Page 6: ...PAGE 6 ...

Page 7: ...that is absolutely to observe In case of non observance malfunctions and even system errors are possible 1 2 Safety The unit described has been designed to the latest technical parameters and complies with all current national and international safety requirements It operates on a high level of reliability because of long term experience in de velopment and constant and strict quality control in o...

Page 8: ...uthorised users only The unit must be operated in good working order only Any conversions or alterations to the unit or to parts of the unit including software must be carried out by trained personnel authorised by the manufacturer Any conversions or alterations carried out by other persons lead to a complete exemption of liability Only specially qualified personnel are authorised to remove and ov...

Page 9: ...ons of the MAGIC DABMUX plus are integrated in a full 19 x 1U housing with an including a wide area power supply as well as an internal fan Figure 1 MAGIC DABMUX plus Front View Figure 2 MAGIC DABMUX plus Rear View with Dual LAN Module ...

Page 10: ...ocol from external Multiplexers As output signal the Multiplexer supplies an EDI signal for transmission to the transmitters The synchronisation is done via NTP The configuration operation and monitoring are carried out via a HTML5 web browser An alarm can also be signalled via SNMP The system has three GBit Ethernet network interfaces each allows the configuration of up to three IP addresses as w...

Page 11: ...ambient temperature of the system should be within the range of 5 C and 45 C This threshold is specially to observe if the system is inserted in a rack The temperature of the system can be displayed via the System Monitor of the web interface During operation humidity must range between 5 and 85 Incorrect ambient temperature and humidity can cause functional deficiencies Operation outside the thre...

Page 12: ...t of the system and boot from SD card 2 4 Operational elements on the front side 2 4 1 LEDs The system has two multicolour LEDs POWER Static green System is booted Red flashing System is booting STATUS Static green No alarm Static orange Indicates a pending warning Static red Indicates a pending alarm 2 4 2 Display The colour display LCD has a resolution of 320 x 240 pixels and is used for basic c...

Page 13: ...s e g letters Selection is made by pressing the knob 2 4 4 Keypad OPT Key o To select the options of a menu ESC Key o To cancel the last configuration or jump to the previous menu INFO Key o Displays the system status MENU Key o Opens the configuration menu 0 9 Key o For entering of digits e g IP address ...

Page 14: ...ng assignment is valid LAN 1 o Default IP Address 192 168 96 102 Subnet Mask 255 255 255 0 o Embedded Basic Web Interface for Firmware Updates LAN 2 o Default IP Address 192 168 96 103 Subnet Mask 255 255 255 0 o Web Interface for DAB Multiplexer application EDI AVTMUX NTP SNMP and Configuration LAN 3 o Currently no function ...

Page 15: ...b browser simultaneously We recommend using one of the following web browsers Firefox version 47 or higher Google Chrome version 53 or higher Safari version 9 or higher also on iPad or iPhone Internet Explorer version 11 or higher After entering the IP address into the address line of your browser you should be automatically connected to MAGIC DABMUX plus and shows the dashboard ...

Page 16: ...PAGE 16 ...

Page 17: ...le CAT5 or higher Max cable length 100 m 2 TX Data out 3 RX Data in 4 NC Not used 5 NC Not used 6 RX Data in 7 NC Not used 8 NC Not used 4 2 USB Interfaces The system has two USB2 0 interfaces for future applications Table 2 USB Interfaces Pin Signal Description Electrical characteristics 1 VCC 5V Socket USB 2 0 Type A Max cable length 5 m Recommended cable CAT5 or higher Max cable length 100m 2 D...

Page 18: ...ND2 Ground 7 DAT0 Data 0 8 DAT1 Data 1 9 DAT2 Data 2 4 4 External 12V Power Supply Input The external power supply input can be used for a redundant power supply An optional tabletop power supply is available ID 490222 The type code of the fitting connector is KYCON KPPX 3P Table 4 External 12 Power Supply Input Pin Signal Description Electrical characteristics 1 GND Ground Socket 3 pole KYCON KPJ...

Page 19: ... 100 m Recommended cable CAT5 or higher Max cable length 100m 2 GND Ground Table 6 ETI Output Pin Signal Description Electrical characteristics 1 DATA OUT ETI Out Socket BNC female Amplitude 3 Vpp G 703 Impedance 75 Ω unbalanced Max cable length 100 m Recommended cable CAT5 or higher Max cable length 100m 2 GND Ground Table 7 Clock In Output programmable Pin Signal Description Electrical character...

Page 20: ...ignment of the socket is shown below Table 8 LAN4 LAN5 Interfaces Pin Signal Description Electrical characteristics 1 TX Data out Socket Western 8 pin RJ45 Recommendation IEEE802 3u 100Base TX Data rate Auto neg 100 Mbit s Recommended cable CAT5 or higher Max cable length 100 m 2 TX Data out 3 RX Data in 4 NC Not used 5 NC Not used 6 RX Data in 7 NC Not used 8 NC Not used ...

Page 21: ... according ETSI TS 102 693 Version 1 1 2 o Optional ETI G 703 G 704 Audio services o Max 25 Audio Encoders can be connected o Support of DAB and DAB o Data rates 16 kbps up to 384 kbps o SBR PS Mono Stereo Joint Stereo Dual Channel Control software o Web interface Dimensions W x H x D o 430 mm 44 45 mm 1 U 225 mm Weight o 2 80 kg without mounting brackets Additional Information o Temperature Range...

Page 22: ...PAGE 22 ...

Page 23: ...s already mounted 7 2 Order numbers MAGIC DABMUX plus 804310 Optional Redundant Power Supply 490222 ETI Module 470100 Dual LAN Interface Module 800021 7 3 Software Options Emergency Warning Break In Upgrade 430601 Cable Upgrade 430602 7 4 Declaration of conformity The declaration of conformity you will find at the end of this manual ...

Page 24: ...PAGE 24 ...

Page 25: ...ently please note down the factory number of the unit as well as the software version that you use The factory number is visible in the software under Administration Registration If you bought the system via your local dealer please contact him first 8 3 Repairs If contrary to expectations your unit is defective please fill in the attached Service Request1 and send the unit to the following addres...

Page 26: ...PAGE 26 ...

Page 27: ...T VIEW 9 FIGURE 2 MAGIC DABMUX PLUS REAR VIEW WITH DUAL LAN MODULE 9 FIGURE 3 DAB DAB HEADEND 10 FIGURE 4 FRONT PANEL 12 FIGURE 5 MAGIC DABMUX PLUS REAR VIEW WITH OPTIONAL DUAL LAN MODULE 17 FIGURE 6 MAGIC DABMUX PLUS REAR VIEW WITH OPTIONAL ETI E1 MODULE 17 ...

Page 28: ...PAGE 28 ...

Page 29: ...estriction of the use of certain hazardous substances in electrical and electronic equipment RoHS DieÜbereinstimmungwirdnachgewiesendurchvollständigeEinhaltungfolgenderNormen Theconformityisevidencedbystrictlymeetingthefollowingstandards EN55032 2015 EN61000 4 4 2012 EN55016 2 3 2017 EN61000 4 5 2014 A1 2017 EN55024 2010 A1 2015 EN61000 4 6 2013 EN61000 3 2 2014 EN61000 4 8 2010 EN61000 3 3 2013 E...

Reviews: