Read all instructions before servicing the Aqua-Hot unit. Aqua-

Hot Heating Systems is not liable for damage resulting from 

failing to follow instructions contained in this manual, and any 

other Aqua-Hot documentation relevant to this unit.
•  Read this manual before servicing the Aqua-Hot System 

to reduce the risk of injury to persons or damage to the 

equipment.

• 

The  product  identity  label  contains  specifications  of  the 

unit, to what standards it has been tested, and important 

safety notices.

•  Disconnect electric wiring to the Aqua-Hot System before 

welding or plasma cutting the coach to avoid damage to 

equipment.

•  The Aqua-Hot tank and heating loop operate at 0 PSI (zero 

pressure system). Air pressure to the tank must not exceed 

18 PSI. Exceeding this rating will cause internal damage to 

the Aqua-Hot.

•  Use caution when working on or near any gas systems.
•  DO NOT connect the 12-volt DC power to the Aqua-Hot if the 

vehicle requires welding.

•  At maximum operating temperature, the coolant and vapor 

will be very hot and scalding that may result in serious 

burns or injury. Be aware of hot surfaces.

•  Use special caution when children are present. Children 

must not be allowed to play with the heater or perform 

cleaning and/or maintenance.

•  Installation and repairs may only be carried out by an 

authorized, factory-trained Aqua-Hot technician. The 

heating system must be serviced in accordance with local 

codes, or, in the absence of local codes, follow NFPA 1192. 

National safety regulations must be adhered to.

If the information in this manual is not followed 

exactly, a fire may result, causing property damage, 

personal injury or death.

Introduction to this Document

Welcome to the Aqua-Hot 125DN Service Manual. This 

manual will serve as a guide for diagnosing and repairing the 

Aqua-Hot, how to perform standard maintenance, and guide 

you through troubleshooting procedures to repair the Aqua-Hot. 

This  service  manual  is  designed  to  aid  trained  and  qualified 

technicians to properly service and troubleshoot the Aqua-Hot 

125DN.

Each section in this manual is dedicated to the diagnosis 

of  specific  components  within  the  Aqua-Hot  which  may  be 

inhibiting the operation of the heater. 

Troubleshooting and diagnosis of the Aqua-Hot is most 

efficiently and effectively accomplished with the Aqua-Hot LCD 

display, which will relay in plain-language, diagnosis of many 

Aqua-Hot related issues.

If additional assistance is needed in diagnosing and 

repairing the Aqua-Hot, please contact our Technical Service 

Department at 574-AIR-XCEL (574-247-9235) from 7:00am to 

4:00pm MST Monday through Friday.

As  with  any  appliance,  allow  the  Aqua-Hot  to 

completely  shut  down  BEFORE  disengaging  the 

coach 12V power disconnect.

Figure 5 

Aqua-Hot 5in. LCD

Heat Priority Option:

The Aqua-Hot comes equipped with the three-way valve 

(sometimes known as the summer/winter valve). This controls 

the  flow  of  the  antifreeze  and  water  heating  solution  within 

the Aqua-Hot to deliver either hot water or interior as priority. 

Tapping on this element will change the valve’s orientation. 

When this element displays “INT. HEAT”, this valve is oriented 

to provide interior heat by circulating the heating solution 

throughout the interior heating zone. When the element says 

“HOT WATER”, the valve is oriented so that the heating solution 

is routed to prioritize hot water. 

High Altitude Option:

The Aqua-Hot 125D comes equipped with a High Altitude 

mode that allows the external diesel burner to operate properly 

at high altitudes. It is recommended any time the coach is at 

an altitude higher than 5,000 feet, to activate the High Altitude 

button on the LCD screen. This modifies the fuel pump rate to 

decrease the flow of diesel fuel. This allows for less emissions, 

less carbon build-up, and proper diesel burner operation. 

Figure 2

Figure 3

Important Notes:

• 

A  qualified  installer  or  service  technician  must  perform 

equipment installation or service. Contact Aqua-Hot for 

Factory Authorized Service Centers or Certified Technicians 

located near you at www.aquahot.com/service-help, or call 

us at 574-AIR-XCEL (574-247-9235). Warranty work must 

be performed by an Aqua-Hot Authorized Service Center

• 

Your on-product identity label contains the specifications of 

your unit. Factory settings may be adjusted by the vehicle 

manufacturer, confirm final setting with your dealer.

• 

This  heating  system  has  been  certified  for  installation  in 

recreational vehicles only.

•  Please read this manual and follow instructions to avoid 

injuries during service and/or operation.

The diesel burner is the Aqua-Hot’s primary and most powerful 

heat source, and provides all of the heating and hot water 

needs when cold temperatures exist, and/or when there is 

a high demand for hot water. It can be activated by turning 

the burner on by tapping BURNER to ON on the LCD screen 

shown below. The burner has 2 modes: ON and OFF. While 

ON, the burner will maintain a tank temperature of 180°F and 

minimum temperature of 160°F as needed, using temperature 

readings from the coach interior thermistors. In OFF mode, the 

burner is off and will not provide any heat to the Aqua-Hot tank. 

The electric element has the same functionality as the diesel 

burner. The burner and electric may be ON simultaneously. 

Figure 4

Содержание Aqua-Hot 100 Series

Страница 1: ...Service Manual 100Series AHE 125 DN1...

Страница 2: ...ed by transfer from the heated antifreeze and distilled water solution The heated domestic water then flows through the tempering valve to be mixed with cool water from the fresh water tank to achieve...

Страница 3: ...a Hot please contact our Technical Service Department at 574 AIR XCEL 574 247 9235 from 7 00am to 4 00pm MST Monday through Friday As with any appliance allow the Aqua Hot to completely shut down BEFO...

Страница 4: ...cing disconnect all power supplies DO NOT operate the diesel burner and or electric heating element without antifreeze and distilled water heating solution present in the Aqua Hot s boiler tank Doing...

Страница 5: ...2 Tempering Valve 3 Aqua Hot Controller 4 Antifreeze and Water Heating Solution Tank 5 AC Electric Element 6 AC Activation Relay 7 Plate to plate Heat Exchanger 8 Three Way Valve 9 Zone Air Bleed Val...

Страница 6: ...LCD screen From here the end user will select their interior temperature set points activate or deactivate the diesel burner and the electric element Zone Control 1 Precise zone control display will d...

Страница 7: ...utilized with the Aqua Hot 5in display Using the Aqua Hot with this new display will ensure that you can take advantage of all of the tools and features of this controller Features This new controller...

Страница 8: ...dicates that heat is either not needed or not requested by the zone thermostat 71 This indicates the set point of the coach thermostats The example in Figure 18 is showing the coach thermostat is requ...

Страница 9: ...ones have been directly wired to the Aqua Hot as described in the installation manual Heating sub systems can be activated independent of their control circuits and other control sensors as a means of...

Страница 10: ...ate Ensure the controller is properly oriented reference Figure 32 10 Using the 4 nuts previously removed fasten the controller to the mounting plate 11 Insert the controller and mounting plate into t...

Страница 11: ...to the INPUTS FROM AQUA HOT section HOME Aqua Hot Diagnostics DIAG Locate LLCO Does LLCO display TANK FULL Yes No This fluid level sensor is functioning as intended Replace the controller Troubleshoo...

Страница 12: ...this thermostat Yes No Depress the red button in the center of the high limit thermostat Figure 40 Re test for continuity Does the thermostat now have continuity Yes No This thermostat is functioning...

Страница 13: ...inue troubleshooting to the right Open a hot water faucet within the coach 1 1 2 2 Figure 47 Continue trouble shooting here Low Temperature Cutoff Thermostat Introduction The Low Temperature Cutoff Th...

Страница 14: ...s of the Three Way Valve to ensure it is out of the way 6 On the top of the Three Way Valve move the two 2 constant tension clamps AWAY from the tee fitting so that they are as far from the barb as po...

Страница 15: ...the Aqua Hot and slide the red and blue PEX through their ports in the front face of the Aqua Hot Use soapy water as necessary to lubricate the PEX going through the rubber grommets in the ports DO NO...

Страница 16: ...Figure 60 If no functionality replace the AC electric relay Figure 59 If tank temperature is not 180 F check element for 11 2 13 amps Replace the Electric element This AC Electric system is operating...

Страница 17: ...switch the electric heating element on and off in conjunction with the interior switch panel and ETS module even though the electric element is on a separate circuit Troubleshooting Procedure Trouble...

Страница 18: ...ely the same Yes This ETS module is functioning as intended Disconnect the ETS module from its leads on the wire harness Navigate back to the INPUTS FROM AQUA HOT section of the LCD screen No Yes No D...

Страница 19: ...Requirements Parts needed PLX 125 HA1 High Altitude Kit Potential other parts needed PLE 125 FL1 Kit 100 Series Fuel Line only if fuel lines are damaged PLX 125 003 Fuel Filter 100 Series only if fue...

Страница 20: ...Pins Figure 79 1 2 Ground goes to Pin 1 Power goes to Pin 2 If you would rather use a plug instead of the wire and gator clips the mating part numbers needed for the connector are Housing 1 967644 1 T...

Страница 21: ...uction A lack of interior heat or hot water when provided with adequate heat from either the electric element and or the diesel burner can be attributed to an overheat thermostat the Aqua Hot controll...

Страница 22: ...rner Troubleshooting This section will cover any issues with the external diesel burner The diesel burner is the primary heat source to the 125DN The troubleshooting procedures listed below are arrang...

Страница 23: ...or damage Check plumbing lines and circulation pump to make sure they are properly secured and free of any damage Check the fuel pump and circulation pump for any damage Run the burner for 20 minutes...

Страница 24: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 47 p 46 ZONE THERMOSTATS ZONE HEAT EXCHANGERS...

Страница 25: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 49 p 48 EXTERNAL DIESEL BURNER ELECTRIC ELEMENT...

Страница 26: ...de Connectors ELE 014 711 Thermistor Tank Temperature Sensor ELE 102 201 Aqua Hot AC Harness ELE 102 211 Burner DC Harness ELE 400 900 Harness Buehler C20 Pump ELX THM 309 Thermistor 10K NTC Room Temp...

Страница 27: ...00 Low Temperature Cutoff Thermostat w Spade Terminals ELX 2E7 102 125DN Element 1 NPSM 120 VAC 1500W Heating MSX 907 162 Refractometer EXE 103 0EX Heat Exchanger Cozy III PLX CTB 290 Clamp Hose Const...

Страница 28: ...that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration screw u...

Страница 29: ...Heating Systems LLC 7501 Miller Drive Frederick CO 80504 Visit us online at www aquahot com Call us at 574 AIR XCEL 574 247 9235 2022 Aqua Hot Heating Systems LLC Printed in the USA Service Manual 10...

Отзывы: