background image

Tempering Valve

Three-Way Valve

©Aqua-Hot®

 125-DN1 Service Manual 

REV 220421

©Aqua-Hot®

 125-DN1 Service Manual 

REV 220421

p. 27

p. 26

• 

There may be residual fluid that exits the fittings - 

use towels or other clean up items as necessary.

9.  Carefully remove the Three-Way Valve from the last ¾” 

heater hose on the right of the valve.

• 

There may be residual fluid that exits the fittings - 

use towels or other clean up items as necessary.

10.  Remove constant tension clamp from the brass of the 

Three-Way Valve on the right, and place it on the new Three-

Way Valve in the same position on the brass.

11. 

Discard the old valve and fittings.

12. Using a nylon wire brush, clean the threads of the PEX 

fitting so that it is free of leftover thread sealant.

13.  Carefully insert the single barb back into the heater hose 

that the old valve was attached to.

14.  Add thread sealant (454 Loctite or better) to the threads of 

the PEX fitting.

15. 

Using a wrench, thread the PEX fitting into the three-way 

valve.

•  3-6 rotations

•  DO NOT BRACE ON THE BLUE PLASTIC WHEN 

TIGHTENING. This may damage the mechanism or 

electrical components.

16.  Install the hoses on the tee on the top of the valve.
17.  Move the constant tension hose clamps to just behind the 

barb of each fitting.

•  Left side of the tee on the top of the 3-way valve.

•  Right side of the tee on the top of the 3-way valve.

•  Right side of the 3-way valve, off the brass onto the 

hose.

18.  Connect the electrical wire from the valve to the DC harness.
19.  Reinstall the side panel and lid using the saved screws and 

washers from Step 2.

20. 

Refill the unit with the coolant saved from Step 1.

•  Add more coolant is needed.

• 

Monitor  the  newly  installed  parts  and  fittings  for 

leaks.

Replacement Procedure:

1.  Drain coolant from system.

•  Pour into a bucket to be reused later.

2.  Remove top and side panels from the Aqua-Hot.

•  Save screws and washers to reuse later

3.  Locate the Three-Way Valve in the Aqua-Hot.

4.  Disconnect the electrical connection from the Three-Way 

Valve to the DC harness.

5.  On the right side of the Three-Way Valve, move the constant 

tension clamp onto the brass of the Three-Way Valve to 

ensure it is out of the way.

6.  On the top of the Three-Way Valve, move the two (2) 

constant tension clamps AWAY from the tee fitting so that 

they are as far from the barb as possible.

7.  On the left of the Three-Way Valve, unscrew the brass PEX 

fitting from the Three-Way Valve using a wrench.

• 

There may be residual fluid that exits the fittings - 

use towels or other clean up items as necessary.

8.  Remove ¾” heater hose from the tee on the top of the 

Three-Way Valve.

DO NOT remove the rivets securing the side panel into place. 

Attempting to do so risks irreparable damage to the boiler 

tank of the Aqua-Hot

Before replacing the 3-way valve, you must purchase the repair 

kit. The Repair Kit should include:
•  Three-Way Valve
•  Black Nylon tee adapter
•  Black Nylon barb adapter
•  2-Pin electrical connector

Figure 49

NOTE: 

Adjusting the mixing valve beyond 120°F 

will result in a lack of hot water and may result in 

scalding. Do NOT attempt to adjust the tempering 

valve without assistance from Aqua-Hot Technical 

Support or a qualified Aqua-Hot technician.

Activate the Aqua-Hot’s diesel 

burner to provide as much heat 

as possible to the boiler tank. 

This test cannot be completed 

with only the electric element.

Open the shower head 

valve within the coach to 

its hottest setting.

Place one hand on the red 

PEX tubing, and before 

the tempering valve  and 

outside the Aqua-Hot.

Are both the red PEX and 

just before the tempering 

valve warm while hot 

water is running?

This tempering valve 

is functioning as 

intended.

Replace the 

tempering 

valve.

Yes

No

Testing Procedure:

Follow the testing procedure to the right in order to diagnose 

the tempering valve. Troubleshoot the tempering valve if the 

following conditions have occurred:
•  A lack of hot water.
•  Hot water supply is uneven.
•  Hot water is too hot.

Three-Way Valve

Figure 48

Tempering Valve

Introduction:

The tempering valve of the Aqua-Hot mixes the hot domestic 

water from the interior of the Aqua-Hot with cold incoming 

domestic water to temper it to a threshold where scalding will 

not occur.

NOTE: 

The side panel has been made transparent in the 

view above to aid in the explanation of the repair. DO NOT 

remove the side panel - only remove the service panels. 

Doing so risks irreparable damage to the Aqua-Hot.

Figure 50

Содержание Aqua-Hot 100 Series

Страница 1: ...Service Manual 100Series AHE 125 DN1...

Страница 2: ...ed by transfer from the heated antifreeze and distilled water solution The heated domestic water then flows through the tempering valve to be mixed with cool water from the fresh water tank to achieve...

Страница 3: ...a Hot please contact our Technical Service Department at 574 AIR XCEL 574 247 9235 from 7 00am to 4 00pm MST Monday through Friday As with any appliance allow the Aqua Hot to completely shut down BEFO...

Страница 4: ...cing disconnect all power supplies DO NOT operate the diesel burner and or electric heating element without antifreeze and distilled water heating solution present in the Aqua Hot s boiler tank Doing...

Страница 5: ...2 Tempering Valve 3 Aqua Hot Controller 4 Antifreeze and Water Heating Solution Tank 5 AC Electric Element 6 AC Activation Relay 7 Plate to plate Heat Exchanger 8 Three Way Valve 9 Zone Air Bleed Val...

Страница 6: ...LCD screen From here the end user will select their interior temperature set points activate or deactivate the diesel burner and the electric element Zone Control 1 Precise zone control display will d...

Страница 7: ...utilized with the Aqua Hot 5in display Using the Aqua Hot with this new display will ensure that you can take advantage of all of the tools and features of this controller Features This new controller...

Страница 8: ...dicates that heat is either not needed or not requested by the zone thermostat 71 This indicates the set point of the coach thermostats The example in Figure 18 is showing the coach thermostat is requ...

Страница 9: ...ones have been directly wired to the Aqua Hot as described in the installation manual Heating sub systems can be activated independent of their control circuits and other control sensors as a means of...

Страница 10: ...ate Ensure the controller is properly oriented reference Figure 32 10 Using the 4 nuts previously removed fasten the controller to the mounting plate 11 Insert the controller and mounting plate into t...

Страница 11: ...to the INPUTS FROM AQUA HOT section HOME Aqua Hot Diagnostics DIAG Locate LLCO Does LLCO display TANK FULL Yes No This fluid level sensor is functioning as intended Replace the controller Troubleshoo...

Страница 12: ...this thermostat Yes No Depress the red button in the center of the high limit thermostat Figure 40 Re test for continuity Does the thermostat now have continuity Yes No This thermostat is functioning...

Страница 13: ...inue troubleshooting to the right Open a hot water faucet within the coach 1 1 2 2 Figure 47 Continue trouble shooting here Low Temperature Cutoff Thermostat Introduction The Low Temperature Cutoff Th...

Страница 14: ...s of the Three Way Valve to ensure it is out of the way 6 On the top of the Three Way Valve move the two 2 constant tension clamps AWAY from the tee fitting so that they are as far from the barb as po...

Страница 15: ...the Aqua Hot and slide the red and blue PEX through their ports in the front face of the Aqua Hot Use soapy water as necessary to lubricate the PEX going through the rubber grommets in the ports DO NO...

Страница 16: ...Figure 60 If no functionality replace the AC electric relay Figure 59 If tank temperature is not 180 F check element for 11 2 13 amps Replace the Electric element This AC Electric system is operating...

Страница 17: ...switch the electric heating element on and off in conjunction with the interior switch panel and ETS module even though the electric element is on a separate circuit Troubleshooting Procedure Trouble...

Страница 18: ...ely the same Yes This ETS module is functioning as intended Disconnect the ETS module from its leads on the wire harness Navigate back to the INPUTS FROM AQUA HOT section of the LCD screen No Yes No D...

Страница 19: ...Requirements Parts needed PLX 125 HA1 High Altitude Kit Potential other parts needed PLE 125 FL1 Kit 100 Series Fuel Line only if fuel lines are damaged PLX 125 003 Fuel Filter 100 Series only if fue...

Страница 20: ...Pins Figure 79 1 2 Ground goes to Pin 1 Power goes to Pin 2 If you would rather use a plug instead of the wire and gator clips the mating part numbers needed for the connector are Housing 1 967644 1 T...

Страница 21: ...uction A lack of interior heat or hot water when provided with adequate heat from either the electric element and or the diesel burner can be attributed to an overheat thermostat the Aqua Hot controll...

Страница 22: ...rner Troubleshooting This section will cover any issues with the external diesel burner The diesel burner is the primary heat source to the 125DN The troubleshooting procedures listed below are arrang...

Страница 23: ...or damage Check plumbing lines and circulation pump to make sure they are properly secured and free of any damage Check the fuel pump and circulation pump for any damage Run the burner for 20 minutes...

Страница 24: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 47 p 46 ZONE THERMOSTATS ZONE HEAT EXCHANGERS...

Страница 25: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 49 p 48 EXTERNAL DIESEL BURNER ELECTRIC ELEMENT...

Страница 26: ...de Connectors ELE 014 711 Thermistor Tank Temperature Sensor ELE 102 201 Aqua Hot AC Harness ELE 102 211 Burner DC Harness ELE 400 900 Harness Buehler C20 Pump ELX THM 309 Thermistor 10K NTC Room Temp...

Страница 27: ...00 Low Temperature Cutoff Thermostat w Spade Terminals ELX 2E7 102 125DN Element 1 NPSM 120 VAC 1500W Heating MSX 907 162 Refractometer EXE 103 0EX Heat Exchanger Cozy III PLX CTB 290 Clamp Hose Const...

Страница 28: ...that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration screw u...

Страница 29: ...Heating Systems LLC 7501 Miller Drive Frederick CO 80504 Visit us online at www aquahot com Call us at 574 AIR XCEL 574 247 9235 2022 Aqua Hot Heating Systems LLC Printed in the USA Service Manual 10...

Отзывы: