Fluid Circulation Pump

Tempering Valve

©Aqua-Hot®

 125-DN1 Service Manual 

REV 220421

©Aqua-Hot®

 125-DN1 Service Manual 

REV 220421

p. 29

p. 28

Replacement Procedure:

1.  Shut off the external domestic water connection, and open 

a hot water faucet valve within the coach to relieve the 

water pressure.

2.  Open the domestic water drain valve on the Aqua-Hot and 

release water in the system.

• 

Attach hose to the ½” PEX barb to release fluid without 

spilling throughout the coach

•  Ensure that the hose does not rise from the drain valve 

otherwise proper drainage will not happen.

3.  Disconnect the coach side domestic water connections
4.  Remove the top cover and side covers of the Aqua-Hot to 

gain access to the interior components.

•  Save the screws and washers to be reused later.

5. 

Using a ⅜” (10mm) socket, remove the nut which secures 

the domestic water valve assembly to the side of the Aqua-

Hot cabinet (shown below).

6. 

Disconnect the swivel fittings attached to the brass tees on 

the tempering valve.

• 

One swivel fitting is attached to the red PEX and the 

other is attached to the blue PEX.

• 

There may be residual fluid in the lines. Use clean-up 

items and tools as needed.

7.  Remove the P-clamp from the stud on the wall of the Aqua-

Hot. Save the P-clamp for reuse later.

8.  Slide the tempering valve assembly gently backwards 

towards the coolant tank until the PEX tubes of the 

assembly are no longer protruding from the Aqua-Hot.

•  Ensure you do not collide with the controller or damage 

any other components in the Aqua-Hot.

9.  Remove the assembly from the Aqua-Hot.
10. 

Remove all three fittings from the tempering valve as shown 

below.

11.  Discard the defunct mixing valve.
12. 

Using Teflon tape and domestic water safe thread sealant, 

reinstall all fittings to previous orientations.

13.  Place previous P-clamp onto the assembly before inserting 

into the Aqua-Hot.

14.  Insert repaired assembly into the Aqua-Hot and slide the 

red and blue PEX through their ports in the front face of the 

Aqua-Hot.

•  Use soapy water as necessary to lubricate the PEX 

going through the rubber grommets in the ports.

•  DO NOT SPRAY ELECTRICAL COMPONENTS AND WIRES 

WITH SOAPY WATER.

15. 

Connect the swivel fittings back to their respective places 

on the assembly.

• 

Do NOT over-tighten the swivel fittings.

16.  Using the nut from Step 5, tighten down the P-clamp on the 

assembly.

17.  Reattach the domestic water lines and check for leaks 

before replacing the side and top panels of the Aqua-Hot.

18.  After checking for leaks, replace the side and top panels of 

the Aqua-Hot using the screws from Step 4.

Figure 51

Figure 52

Figure 53

Fluid Circulation Pump

Introduction:

The fluid circulation pump operates to provide fluid circulation 

to either the interior heating zone or the antifreeze boiler tank 
depending on the heating and hot water needs at the time.

Troubleshooting Procedure:

If the fluid circulation pump has failed, it will typically indicate 

an over-current fault on the controller fault log. If this is the case, 

the fault must be verified before replacing the circulation pump. 

Follow the procedure to diagnose the fluid circulation pump.

Power cycle the Aqua-Hot 

to clear any current faults.

Locate the Aqua-Hot LCD 

screen. Navigate to the 

TESTING page (Figure 56a).

Activate the internal 

circulation pump, and if 

necessary the boost pump

Does the suspect pump 

activate?

Navigate to the faults page 

(Figure 56b).

Using a multi-meter, test 

for voltage between pins 

J6-7 and J6-8.

No

Yes

Is voltage present between 

these pins?

Navigate to the TEST tab 

and activate the internal 

circulation pump

No

Yes

Replace the 

circulation 

pump

Replace the 

Aqua-Hot 

controller

Yes

Are any pump over-current 

faults displayed?

Replace the 

circulation 

pump

This pump is 

operating as 

intended.

No

Figure 54

NOTE: 

The side panel has been made transparent in the 

view above to aid in the explanation of the repair. DO NOT 

remove the side panels. Doing so risks irreparable damage 

to the Aqua-Hot.

Figure 56a

Figure 56b

Figure 55

Содержание Aqua-Hot 100 Series

Страница 1: ...Service Manual 100Series AHE 125 DN1...

Страница 2: ...ed by transfer from the heated antifreeze and distilled water solution The heated domestic water then flows through the tempering valve to be mixed with cool water from the fresh water tank to achieve...

Страница 3: ...a Hot please contact our Technical Service Department at 574 AIR XCEL 574 247 9235 from 7 00am to 4 00pm MST Monday through Friday As with any appliance allow the Aqua Hot to completely shut down BEFO...

Страница 4: ...cing disconnect all power supplies DO NOT operate the diesel burner and or electric heating element without antifreeze and distilled water heating solution present in the Aqua Hot s boiler tank Doing...

Страница 5: ...2 Tempering Valve 3 Aqua Hot Controller 4 Antifreeze and Water Heating Solution Tank 5 AC Electric Element 6 AC Activation Relay 7 Plate to plate Heat Exchanger 8 Three Way Valve 9 Zone Air Bleed Val...

Страница 6: ...LCD screen From here the end user will select their interior temperature set points activate or deactivate the diesel burner and the electric element Zone Control 1 Precise zone control display will d...

Страница 7: ...utilized with the Aqua Hot 5in display Using the Aqua Hot with this new display will ensure that you can take advantage of all of the tools and features of this controller Features This new controller...

Страница 8: ...dicates that heat is either not needed or not requested by the zone thermostat 71 This indicates the set point of the coach thermostats The example in Figure 18 is showing the coach thermostat is requ...

Страница 9: ...ones have been directly wired to the Aqua Hot as described in the installation manual Heating sub systems can be activated independent of their control circuits and other control sensors as a means of...

Страница 10: ...ate Ensure the controller is properly oriented reference Figure 32 10 Using the 4 nuts previously removed fasten the controller to the mounting plate 11 Insert the controller and mounting plate into t...

Страница 11: ...to the INPUTS FROM AQUA HOT section HOME Aqua Hot Diagnostics DIAG Locate LLCO Does LLCO display TANK FULL Yes No This fluid level sensor is functioning as intended Replace the controller Troubleshoo...

Страница 12: ...this thermostat Yes No Depress the red button in the center of the high limit thermostat Figure 40 Re test for continuity Does the thermostat now have continuity Yes No This thermostat is functioning...

Страница 13: ...inue troubleshooting to the right Open a hot water faucet within the coach 1 1 2 2 Figure 47 Continue trouble shooting here Low Temperature Cutoff Thermostat Introduction The Low Temperature Cutoff Th...

Страница 14: ...s of the Three Way Valve to ensure it is out of the way 6 On the top of the Three Way Valve move the two 2 constant tension clamps AWAY from the tee fitting so that they are as far from the barb as po...

Страница 15: ...the Aqua Hot and slide the red and blue PEX through their ports in the front face of the Aqua Hot Use soapy water as necessary to lubricate the PEX going through the rubber grommets in the ports DO NO...

Страница 16: ...Figure 60 If no functionality replace the AC electric relay Figure 59 If tank temperature is not 180 F check element for 11 2 13 amps Replace the Electric element This AC Electric system is operating...

Страница 17: ...switch the electric heating element on and off in conjunction with the interior switch panel and ETS module even though the electric element is on a separate circuit Troubleshooting Procedure Trouble...

Страница 18: ...ely the same Yes This ETS module is functioning as intended Disconnect the ETS module from its leads on the wire harness Navigate back to the INPUTS FROM AQUA HOT section of the LCD screen No Yes No D...

Страница 19: ...Requirements Parts needed PLX 125 HA1 High Altitude Kit Potential other parts needed PLE 125 FL1 Kit 100 Series Fuel Line only if fuel lines are damaged PLX 125 003 Fuel Filter 100 Series only if fue...

Страница 20: ...Pins Figure 79 1 2 Ground goes to Pin 1 Power goes to Pin 2 If you would rather use a plug instead of the wire and gator clips the mating part numbers needed for the connector are Housing 1 967644 1 T...

Страница 21: ...uction A lack of interior heat or hot water when provided with adequate heat from either the electric element and or the diesel burner can be attributed to an overheat thermostat the Aqua Hot controll...

Страница 22: ...rner Troubleshooting This section will cover any issues with the external diesel burner The diesel burner is the primary heat source to the 125DN The troubleshooting procedures listed below are arrang...

Страница 23: ...or damage Check plumbing lines and circulation pump to make sure they are properly secured and free of any damage Check the fuel pump and circulation pump for any damage Run the burner for 20 minutes...

Страница 24: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 47 p 46 ZONE THERMOSTATS ZONE HEAT EXCHANGERS...

Страница 25: ...System Schematics System Schematics Aqua Hot 125 DN1 Service Manual REV 220421 Aqua Hot 125 DN1 Service Manual REV 220421 p 49 p 48 EXTERNAL DIESEL BURNER ELECTRIC ELEMENT...

Страница 26: ...de Connectors ELE 014 711 Thermistor Tank Temperature Sensor ELE 102 201 Aqua Hot AC Harness ELE 102 211 Burner DC Harness ELE 400 900 Harness Buehler C20 Pump ELX THM 309 Thermistor 10K NTC Room Temp...

Страница 27: ...00 Low Temperature Cutoff Thermostat w Spade Terminals ELX 2E7 102 125DN Element 1 NPSM 120 VAC 1500W Heating MSX 907 162 Refractometer EXE 103 0EX Heat Exchanger Cozy III PLX CTB 290 Clamp Hose Const...

Страница 28: ...that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration screw u...

Страница 29: ...Heating Systems LLC 7501 Miller Drive Frederick CO 80504 Visit us online at www aquahot com Call us at 574 AIR XCEL 574 247 9235 2022 Aqua Hot Heating Systems LLC Printed in the USA Service Manual 10...

Отзывы: