Appendix
System Schematics
©Aqua-Hot®
125-DN1 Service Manual
REV 220421
©Aqua-Hot®
125-DN1 Service Manual
REV 220421
p. 55
p. 54
Parts
AC Relay
Cover, AC Element Cover for 125DN & 100DE
Kit, Fuel Line, 125DN
Kit, High Altitude Assembly, 125DN
Kit, Coach-Side Controller Components
Properly Apply Antifreeze to the Prism Assembly
Use the guide below to properly apply the ethylene glycol
mixture to the prism assembly of the refractometer. Once that
is complete, peer through the eyeglass of the refractometer to
continue to the next step.
Adjust the Boundary Line
Once the glycol solution has been properly applied, adjust the
calibration screw until the boundary line labeled “Ethylene
Glycol” is set to 32°F. The graphic to the right has been designed
as an aid, but note that it may differ from what is shown in the
refractometer sight glass.
Measuring Antifreeze Using a Refractometer
Eye Piece
Prism Assembly
Daylight Plate
Assembly
Calibration Screw
Refractometer Sight Glass
Boundary Line
Adjust to 32°F
Upper Blue
Field
Lower White
Field
Poor
Poor
Good
Application of Propylene Glycol
Poor
Poor
Good
Application of Ethylene Glycol