Service Manual - KXL DCI
12-9
12.7.3 Compressor
Overheating Protection
12.7.3.1
Compressor Overheating Protection for GC 24/30 DCI
CTT Trend
CTT
Cool Heat
Fast
Decreasing
Decreasing No
Change
Increasing Fast
Increasing
CTT
>
105
CTT
>
105
SC SC
SC
SC SC
100
≤
CTT
<
105 100
≤
CTT
<
105
D1 D1
D2
D2 D2
98
≤
CTT
<
100 95
≤
CTT
<
100
SR SR
D1
D2 D2
93
≤
CTT
<
100
85
≤
CTT
<
95
SR SR
SR
D1 D1
90
≤
CTT
≤
93
80
≤
CTT
≤
85
Norm Norm
Norm SR SR
CTT
<
90
CTT
<
80
Norm
12.7.4
Heat Sink Overheating Protection
12.7.4.1 Heat Sink Overheating Protection For GC 24/30 DCI
Delta HST
HST
<-2 -2
-1,0,1
2 >2
HST
≥
81
SC SC
SC
SC SC
79
≤
HST <
81
D1
D1
D2
D2
D2
75
≤
HST <
79
SR SR
D1
D2 D2
73
≤
HST<
75
SR SR
SR
D1 D1
71
≤
HST
≤
73
Norm Norm
SR
SR
SR
HST <
71
Norm
12.7.5
System Over Power Protection Only For GC 24/30 DCI
Delta PWR
Power
PWR1 PWR2
<
-2000
[
-2000,0
) 0 (0,
2000
] >
2000
PWR
≥
3500
PWR
≥
2900
SC SC SC SC SC
3300
≤
PWR <
3500
2750
≤
PWR <
2900
D1
D1
D2
D2
D2
3100
≤
PWR <
3300
2600
≤
PWR <
2750
SR SR D1 D2 D2
3000
≤
PWR <
3100
2450
≤
PWR <
2600
SR SR SR D1 D1
2950
≤
PWR
≤
3000
2300
≤
PWR
≤
2450
Norm Norm Norm SR SR
PWR <
2950
PWR <
2300
Norm
There are two sets of OVRPWR values, the selection of the values are set according to the state of
the Power-Shed input.
Power-Shed input open
Æ
Set values 1
Power-Shed input sort
Æ
Set values 2