INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR CASED PUREAIR™ MODELS PCO-12C-2, PCO-20C-2

Shipping and Packing List

Unique Supplies

General

Package 1 of 1 contains:

1 - PureAir™ air purification system c/w:

1 - Metal cabinet, including insulated door

1 - One piece slide-in assembly

(Metal Frame and

ballasts, with associated wiring.)

1 - MERV 9, 4" pleated filter
4 - Installed UVA lamps (PCO-12C)
6 - Installed UVA lamps (PCO-20C)
1 - 

Separately wrapped titanium dioxide metal insert

1 - Power cord
1 - Installation and maintenance instructions
1 - Homeowners IAQ Guide
1 - Warranty certificate
1 - Registration card

• Cotton gloves and cloth (to remove finger prints

from lamps.)

• Sealant: Aluminum foil duct tape or water based

mastic. (NOT silicone)

The PureAir™ air purification system helps to signifi-
cantly reduce levels of airborne volatile organic
compounds, cooking odors, common household
odors, airborne dust particles, mold spores, and
pollen in residential spaces. The PureAir™ air purifi-
cation system 

(cased model)

includes a MERV 9

pleated filter, UVA lamps, and a metal insert that is
coated with a titanium dioxide catalyst. As air enters
the system, a percentage of airborne particles and
bioaerosols, such as mold and bacteria, ranging in
size down to .3 microns, are captured by the pleat-
ed filter. The smaller airborne particles, odors, and
chemicals continue through the system. The UVA
lamp activates the catalyst on the metal insert. The
catalyst combines with water vapor in the air to form
hydroxyl radicals that destroy a percentage of the
remaining odors and chemicals.

In laboratory & field tests, we found greater than

(TVOC) within 24 hours of initial installation and
operation of the PureAir™ air purification system.
When the system is first started, it may take up to 48
hours to reduce the airborne chemicals that have
built up in your home over a long period of time.
After that period, there will be a balance between
chemicals emitted inside your home and chemicals
removed by your PureAir™ air purification system.
Please refer to the included Homeowners IAQ guide
for other measures to improve indoor air quality.

The PureAir™ air purification system is NOT intended to be used for
removal of active mold growth or continuous source of high levels
of chemicals in the air. For existing mold growth, the mold must be
appropriately removed PRIOR to installation of your PureAir™ air
purification system.

212361-03 Rev. 1B 8/03

Risk of property damage, injury, or death.

Installation, adjustments, alterations, service and
maintenance must be performed by a qualified
service technician.

WARNING

©2003 Lennox Industries, Inc.

Dallas, Texas USA

Possible odor emissions.

Odors may be present temporarily after initial start-
up, painting, cleaning, remodeling, hobby activities or
after lamp replacement.

Some occupants may notice irritation or discomfort
during this period.

If irritation or discomfort persists longer than 48
hours, unplug the PCO device and contact your
Lennox authorized dealer.

NOTICE

Electric shock hazard.

Can cause injury or death.

Disconnect all remote electrical
power supplies before servicing.

Access panels must be in place dur-
ing the appliance operation.

WARNING

Содержание PureAir PCO-12C-2

Страница 1: ...atalyst combines with water vapor in the air to form hydroxyl radicals that destroy a percentage of the remaining odors and chemicals In laboratory field tests we found greater than TVOC within 24 hours of initial installation and operation of the PureAir air purification system When the system is first started it may take up to 48 hours to reduce the airborne chemicals that have built up in your ...

Страница 2: ...0 F 140 F 18 C 60 C Outside of duct 10 60 relative humidity PCO has optimal per formance at 50 relative humidity PLEATED FILTER EFFICIENCY Minimum Efficiency Rating Value MERV 9 Tested to ASHRAE Standard 52 2 Dimensions Specifications LISTINGS ETL Safety Listing Report J99 9379 001 Conforms to UL STD 1598 Certified to CSA STD C22 2 NO 250 0 Specifications subject to change without notice 11 5 8 19...

Страница 3: ...dous to your health Take care when handling lamps If lamp is broken avoid contact with mercury CAUTION Sharp edges hazard Equipment sharp edges can cause injuries Use protective gloves when grasping equipment edges CAUTION Fig 2 Verify proper installation of lamps CHECKING THE LAMPS Fig 2 Lamps are factory installed as shown below Make sure that the lamps have not become disengaged during shipping...

Страница 4: ...handler s should be sealed to prevent contamination from unconditioned spaces such as basements garages or attics Optionally the cabinet can be strap mounted from the ceiling When drilling screw holes in the cabinet for straps be sure to locate them where they do not inter fere with the insertion of the PCO 12C 20C assembly Airflow direction INSTALLING THE CABINET Cont d INSTALLING THE ASSEMBLY Fi...

Страница 5: ...d Use Lennox blower relay part number 45H03 Lennox utilizing the Lennox Surelight heating control do not require the use of an additional blower relay Operation WIRING INSTRUCTIONS See wiring diagrams The PCO 12C 20C must be wired in accordance with national and local codes IMPORTANT To ensure UVA lamps life power MUST remain on to PCO 12C 20C at all times Do not interlock with air handler blower ...

Страница 6: ...tall access door 5 Reconnect power cord 6 Verify that the lamps are illuminated METAL INSERT LAMP REPLACEMENT Cont d 6 Install new metal insert 7 Slide assembly back into cabinet and install access door 8 Reconnect power cord 9 Verify that the lamps are illuminated Note DO NOT WASH metal insert Washing will destroy the titanium dioxide catalyst that coats the insert surface Note If the system has ...

Страница 7: ...8 49M48 Contact your local Lennox dealer to order replacement parts For the Lennox dealer nearest you dial 1 800 9 LENNOX Visit us at http www Lennox com 7 LAMP DISPOSAL Hg LAMP CONTAINS MERCURY Manage in accord with disposal laws Refer to www lamprecycle org or call 1 800 9 LENNOX LAMP CHECKOUT Does not illuminate 1 Check power cord for 120V power 2 Unplug power cord and remove access door 3 Slid...

Страница 8: ...ns bulbs and ballast Replace any burned out or damaged components and plug unit in Are Lamps Lit Yes No No Are Lamps Lit Are Lamps Lit Did Lamps Light Check power supply Breakers Plug Electrical wiring Repair electrical and plug unit in No Yes Continue with maintenance per unit instruction manual Yes Continue with maintenance per unit instruction manual Replace Assembly End End End End Unplug PCO ...

Отзывы: