2-1
PRODUCT DATA SHEET
SM CKDDCI 2-A.3 GB
2.
PRODUCT DATA SHEET
2.1
CKD 036 DCI / GCD 036 DCR
Model Indoor Unit
CKD 036 DCI
Model Outdoor Unit
GCD 036 DCR
Installation Method
CASSETTE
Characteristics
Units
Cooling
Heating
Capacity - Nominal (Minimum ~ Maximum)
(1)
Btu/hr
30,700 (8,900 – 34,120) 35,150 (8,200 – 39,250)
kW
9.0 (2.6 – 10.0)
10.3 (2.4 – 11.5)
Power Input - Nominal (Minimum ~ Maximum)
( (1)
W
3,100 (750 – 3,850)
3,430 (520 – 3,960)
EER (Cooling) / COP (Heating)
(1)
W/W
2.9
3.0
Energy Efficiency Class
-
“C”
“D”
Power Supply
V/Ph/Hz
220-240/1/50
Rated Current (Nominal)
A
13.0
14.4
Starting Current
A
<10
Circuit Breaker Rating
A
25
INDOOR
Fan Type & Quantity
CENTRIFUGAL x1
Fan Speed
H/M/L
RPM
580
540
500
Airflow
(2)
H/M/L
m
3
/hr
1170
1080
990
External Static Pressure
Min-Nom-Max
Pa
-
Sound Power Level
(3)
H/M/L
dB (A)
44
42
40
Sound Pressure Level
(4)
H/M/L
dB (A)
53
51
49
Moisture Removal (Nominal)
L/hr
3.7
Condensate Drain Tube I.D.
mm
19
Dimensions
W/H/D
mm
840
300
840
Weight
kg
32(+6kf Panel)
Package Dimensions
W/H/D
mm
950
317
950
Packaged Weight
kg
40(+6kg Panel)
Units per Pallet
Units
6
Stacking Height
Units
6
OUTDOOR
Refrigerant Control
Electronic Expansion Valve
Compressor Type, Model
Scroll
Motor type
DCBL Inverter
Fan Type & Quantity
Axial 2x 400
Ф
mm
Fan Speed
RPM
1100-100 (continuous)
Airflow
Max
m
3
/hr
4,150
Sound Power Level
Nom C/H
dB (A)
67
69
Sound Pressure Level
(4)
Nom C/H
dB (A)
57
59
Dimensions
W/H/D
mm
900
970
340
Weight
kg
76
Package Dimensions
W/H/D
mm
985
1020
435
Packaged Weight
kg
81
Units per Pallet
Units
6
Stacking Height
Units
2
Refrigerant Type
R410A
Refrigerant Charge (STD connected Tube
Length)
kg (m)
2.5 / 30
Additional Charge
g/m
30
Connections
Between Units
Liquid Line
In (mm)
3/8”
Suction Line
In (mm)
5/8”
Max. Tubing Length
m
70
Max. Height Difference
m
30
Operation Control Type
LCD Remote Control
Heating Elements
kW
BH 70W - optional
Others
(1)
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1.0 meter distance from unit.
Содержание CKD 036
Страница 11: ...4 2 OUTLINE DIMENSIONS SM CKDDCI 2 A 3 GB 4 2 Outdoor Unit GCD 036 DCR 4 3 Outdoor Unit GC 43 DCI...
Страница 26: ...8 1 WIRING DIAGRAMS SM CKDDCI 2 A 3 GB 8 WIRING DIAGRAMS 8 1 Indoor Unit CKD 036 CKD 045 DCI 202052390039...
Страница 35: ...OPTIONAL ACCESSORIES 11 4 SM CKDDCI 2 A 3 GB...
Страница 117: ...15 7 EXPLODED VIEWS AND SPARE PARTS LISTS SM CKDDCI 2 A 3 GB 15 4 3 Outdoor Unit Electronics Assembly...