AirLive IGR-842PoE Скачать руководство пользователя страница 1

IGR-842PoE 

6 port Gigabit PoE with 2 port 
SFP industrial ring manage 
switch

 

Web User Manual 

Содержание IGR-842PoE

Страница 1: ...IGR 842PoE 6 port Gigabit PoE with 2 port SFP industrial ring manage switch Web User Manual...

Страница 2: ...l photocopying or recording without the written consent of OvisLink Corp OvisLink Corp has made the best effort to ensure the accuracy of the information in this user s guide However we are not liable...

Страница 3: ...ry 4 2 4 Knowing your IGR 842POE 5 2 5 Hardware Installation 6 2 6 LED Table 9 3 Introduce the IGR 842POE 11 3 1 Important Information 11 3 2 Prepare your PC 11 3 3 Management Interface 11 3 4 Introdu...

Страница 4: ...oS 170 4 20 Mirroring 192 4 21 GVRP 193 4 22 sFlow 194 4 23 RingV2 197 4 24 DDMI 199 5 Web Management Monitor of IGR 842POE 200 5 1 Sysytem 200 5 2 Green Ethernet 205 5 3 Ports 206 5 4 DHCP 212 5 5 Se...

Страница 5: ...842POE 275 6 1 Ping 275 6 2 Ping6 276 6 3 VeriPHY 277 7 Web Management Maintenance of IGR 842POE 279 7 1 Restart Device 279 7 2 Factory Default 279 7 3 Software 280 7 4 Configuration 282 8 Trouble Sh...

Страница 6: ...e The IGR 842POE is able to work in any demanding environment such as factory or intersection IGR 840POE can be power by two power source for power redundancy to prevent power failure for one power su...

Страница 7: ...for IGR 842POE It is a must read Chapter 2 This chapter is about hardware installation You should read through the entire chapter Chapter 3 3 1 Important Information This section has information of de...

Страница 8: ...Before You Start It is important to read through this section before you install the IGR 842POE The maximum cabling distance is 100 meters by Cat5e RJ45 cable Do not create a network loop Always check...

Страница 9: ...amaged please contact your local dealer for service 2 3 Optional Accessory The IGR 842POE has the following optional accessories which you can purchase from AirLive 1000Base SX MiniGBIC Transceiver Mo...

Страница 10: ...al Note While installing MiniGBIC into SFP slot of IGR 842POE please notice the direction of MiniGBIC is correct and make sure that MiniGBIC is indeed installed in the IGR 842POE 2 4 Knowing your IGR...

Страница 11: ...let nearby The surface where you put your IGR 842POE should be clean smooth level and sturdy Make sure there is enough clearance around the IGR 842POE to allow attachment of cables power cord and allo...

Страница 12: ...anual Screw the din clip with screws in the accessory kit Hook the unit onto the din rail Push the bottom of the unit towards the din rail until it locks in place 2 5 3 Ground Connection IGR 842POE mu...

Страница 13: ...two power supply input range 12V 58V The DC power connector is a 6 pin terminal block There is alarm contact on the middle terminal block 2 5 5 Console Connection The Console port is for local managem...

Страница 14: ...eration status The following table provides descriptions of LED status and their meaning LED Status Description P1 Green P1 power line has power Off P1 power line disconnect or does not have supply po...

Страница 15: ...100 Mbps or a 1000Mbps connection is detected Off No link or a 10 Mbps connection is detected SFP port Link Act Green Ethernet link up Off Ethernet link down SFP port Speed Yellow SFP port speed 1000M...

Страница 16: ...airlive Note The default PoE mode is Disable 3 2 Prepare your PC The IGR 842POE can be managed remotely by a PC through RJ 45 cable The default IP address of the IGR 842POE is 192 168 2 1 with a subn...

Страница 17: ...on to Web Management The IGR 842POE offers Web Management interfaces for users Users can easily access and control IGR 842POE via web browsers The Web Based Management supports Internet Explorer 10 or...

Страница 18: ...Then you will see the port information On the left top corner there is a pull down list for Auto Logout For the sake of security we provide auto logout function to protect you from illegal user as yo...

Страница 19: ...to configure its setting The detailed introduction for all management function will explain in below chapters The following list is the full function tree for web user interface Main Screen Once choos...

Страница 20: ...ation 4 1 1 System Information You can identify the system by configuring the contact information name and location of the switch The switch system information is provided here Web interface To config...

Страница 21: ...ration System Information System Location 4 Button Save Click to save changes Reset Click to revert to previously saved values 4 1 2 System IP This sector is to provide and config the IP information o...

Страница 22: ...will not be routed Router traffic is routed between all interfaces 2 DNS Sever This setting controls the DNS name resolution done by the switch The following modes are supported From any DHCP interfa...

Страница 23: ...his option is enabled the system will configure the IPv4 address and mask of the interface using the DHCP protocol The DHCP client will announce the configured System Name as hostname to provide DNS l...

Страница 24: ...34 The field may be left blank if IPv6 operation on the interface is not desired 9 IPv6 Mask The IPv6 network mask in number of bits prefix length Valid values are between 1 and 128 bits for a IPv6 a...

Страница 25: ...the IPv6 gateway address is link local it must specify the next hop VLAN for the gateway If the IPv6 gateway address is not link local system ignores the next hop VLAN for the gateway Buttons 1 Add In...

Страница 26: ...in 128 bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used a...

Страница 27: ...anagement Monitor of IGR 842POE AirLive IGR 842POE User Manual 22 Web Interface To configure log configuration in the web interface 1 Click Configuration System Time 2 Specify the Time parameter 3 Cli...

Страница 28: ...t Saving Time Configuration 1 Daylight Saving Time This is used to set the clock forward or backward according to the configurations set below for a defined Daylight Saving Time duration Select Disabl...

Страница 29: ...ght Saving Time Range 1 to 1440 3 Non Recurring Configurations Start time settings Week Select the starting week number Day Select the starting day Month Select the starting month Hours Select the sta...

Страница 30: ...ally and revert to previously saved values 4 1 5 System Log Configure System Log on this page Web Interface To configure log configuration in the web interface 1 Click Configuration System Log 2 Speci...

Страница 31: ...2 Acronym Indicates the IPv4 host address of syslog server If the switch provide DNS feature it also can be a host name 3 Syslog Level Indicates what kind of message will send to syslog server Possibl...

Страница 32: ...entry is Enabled then alarm will be shown in alarm history current when it occurs Alarm LED will be on lighted Alarm Relay also be enabled SNMP trap will be sent if any SNMP trap entry exists and enab...

Страница 33: ...nsmitting device has all circuits powered up when traffic is transmitted The devices can exchange wakeup time information using the LLDP protocol Green Ethernet works for ports in auto negotiation mod...

Страница 34: ...n 1 Port The switch port number of the logical port 2 ActiPHY Link down power savings enabled ActiPHY works by lowering the power for a port when there is no link The port is power up for short moment...

Страница 35: ...EEE Urgent Queues Queues set will activate transmission of frames as soon as data is available Otherwise the queue will postpone transmission until a burst of frames can be transmitted Buttons Save C...

Страница 36: ...s the highest speed that is compatible with the link partner 10Mbps HDX Forces the cu port in 10Mbps half duplex mode 10Mbps FDX Forces the cu port in 10Mbps full duplex mode 100Mbps HDX Forces the cu...

Страница 37: ...sly saved values Refresh Click to refresh the page Any changes made locally will be undone 4 4 DHCP The section describes to configure the DHCP Snooping parameters of the switch The DHCP Snooping can...

Страница 38: ...isabled The first VLAN ID must be smaller than or equal to the second VLAN ID BUT if the VLAN range contains only 1 VLAN ID then you can just input it into either one of the first and second VLAN ID o...

Страница 39: ...AN Range Click to add a new VLAN range Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 4 1 2 DHCP Server Excluded IP This page configure...

Страница 40: ...lick to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 4 1 3 DHCP Server Pool This page manages DHCP pools According to the DHCP pool DHCP server wil...

Страница 41: ...pool Buttons Delete Click to delete the setting Add New Pool Click to add a new VLAN range Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved value...

Страница 42: ...bled Enable DHCP snooping mode operation When DHCP snooping mode operation is enabled the DHCP request messages will be forwarded to trusted ports and only allow reply packets from trusted ports Disab...

Страница 43: ...bnet For such condition please make sure the switch configuration of VLAN interface IP address and PVID Port VLAN ID correctly Web Interface To monitor an DHCP Relay statistics in the web interface 1...

Страница 44: ...lient It only works when DHCP relay operation mode is enabled Disabled Disable DHCP relay information mode operation 4 Relay Information Policy Indicates the DHCP relay information option policy When...

Страница 45: ...Add New User 3 Add User Name 4 Add Password 5 Select Privilege level Parameter description 1 User Name A string identifying the user name that this entry should belong to The allowed string length is...

Страница 46: ...upload factory defaults and etc need user privilege level 15 Generally the privilege level 15 can be used for an administrator account privilege level 10 for a standard user account and privilege leve...

Страница 47: ...5 Web Management Monitor of IGR 842POE AirLive IGR 842POE User Manual 42 Parameter description 1 Group Name The name identifying the privilege group In most cases a privilege level group...

Страница 48: ...Load Web Users Privilege Levels and everything in Maintenance Debug Only present in CLI 2 Privilege Level Every group has an authorization Privilege level for the following sub groups configuration re...

Страница 49: ...imed out if the remote servers are offline In this case the next method is tried Each method is tried from left to right and continues until a method either approves or rejects a user If a remote serv...

Страница 50: ...led Enable SSH mode operation Disabled Disable SSH mode operation Buttons Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 5 1 5 HTTPS Co...

Страница 51: ...the HTTPS redirect mode operation It only significant if HTTPS mode Enabled is selected Automatically redirects web browser to an HTTPS connection when both HTTPS mode and Automatic Redirect are enab...

Страница 52: ...gement entry 5 End IP address Indicates the end IP address for the access management entry 6 HTTP HTTPS Indicates that the host can access the switch from HTTP HTTPS interface if the host IP address m...

Страница 53: ...ield SNMP Enable SNMP agent will be started up All supported MIB OIDs including RMON MIB can be accessed via SNMP manager If the field SNMP is set Disable SNMP agent will be de activated the related C...

Страница 54: ...used to restrict source subnet 4 Write Community Indicates the community write access string to permit access to SNMP agent The allowed string length is 0 to 255 and the allowed content is the ASCII c...

Страница 55: ...anual 50 1 Click Configuration SNMP and Trap 2 Click Add New Entry then you can create new SNMP Trap on the switch 3 Click Save Parameter description Global Setting 1 Mode Indicates the trap mode oper...

Страница 56: ...lowed the first character must be an alpha character and the first and last characters must not be a dot or a dash Indicates the SNMP trap destination IPv6 address IPv6 address is in 128 bit records r...

Страница 57: ...dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can appear only once It can also represent a legally valid IPv4...

Страница 58: ...ngine ID mode of operation 18 Trap Security Name Indicates the SNMP trap security name SNMPv3 traps and informs using USM for authentication and privacy A unique security name is needed when traps and...

Страница 59: ...rticular range of source addresses can be used to restrict source subnet when combined with source mask 4 Source Mask Indicates the SNMP access source address mask Button Add New Entry Click to add a...

Страница 60: ...hould belong to Possible security models are NoAuth NoPriv No authentication and no privacy Auth NoPriv Authentication and no privacy Auth Priv Authentication and privacy The value of security level c...

Страница 61: ...and revert to previously saved values 4 5 1 7 5 Group The function is used to configure SNMPv3 group The Entry index key are Security Model and Security Name To create a new group account please check...

Страница 62: ...allowed content is ASCII characters from 33 to 126 Button Add New Entry Click to add a new group entry Save Click to save changes Reset Click to undo any changes made locally and revert to previously...

Страница 63: ...there should be another view entry existing with view type as included and it s OID subtree should overstep the excluded view entry 4 OID Subtree The OID defining the root of the subtree to add to th...

Страница 64: ...owed content is ASCII characters from 33 to 126 3 Security Model Indicates the security model that this entry should belong to Possible security models are any Any security model accepted v1 v2c usm v...

Страница 65: ...oftware agents that collect information and analyze packets These probes act as servers and the Network Management applications that communicate with them act as clients 4 5 1 8 1 Statistics Configure...

Страница 66: ...in the History table The Start from History Index and Sample Index allows the user to select the starting point in the History table Clicking the button will update the displayed table starting from t...

Страница 67: ...m This page provides an overview of RMON Alarm entries Each page shows up to 99 entries from the Alarm table default being 20 selected through the entries per page input field When first visited the w...

Страница 68: ...umber of inbound packets that are discarded even the packets are normal InErrors The number of inbound packets that contained errors preventing them from being deliverable to a higher layer protocol I...

Страница 69: ...3647 11 Falling Index Falling event index 1 65535 Button Add New Entry Click to add a new community entry Save Click to save changes Reset Click to undo any changes made locally and revert to previous...

Страница 70: ...default is a null string 4 Type Indicates the notification of the event the possible types are none No SNMP log is created no SNMP trap is sent log Create SNMP log entry when the event is triggered s...

Страница 71: ...erent actions as described below The Limit Control module utilizes a lower layer module Port Security module which manages MAC addresses learnt on the port The Limit Control configuration consists of...

Страница 72: ...s discussed under Aging Period 3 Aging Period If Aging Enabled is checked then the aging period is controlled with this input If other modules are using the underlying port security for securing MAC a...

Страница 73: ...number cannot exceed 1024 If the limit is exceeded the corresponding action is taken The switch is born with a total number of MAC addresses from which all ports draw whenever a new MAC address is se...

Страница 74: ...the IEEE 802 1X and MAC based authentication system and port settings The IEEE 802 1X standard defines a port based access control procedure that prevents unauthorized access to a network by requiring...

Страница 75: ...Reauthentication Enabled 3 Set Reauthentication Period Default is 3600 seconds 4 Set EAPOL Timeout Default is 30 seconds 5 Set Aging Peroid Default is 300 seconds 6 Set Hold Time Default is 10 second...

Страница 76: ...4 EAPOL Timeout Determines the time for retransmission of Request Identity EAPOL frames Valid values are in the range 1 to 65535 seconds This has no effect for MAC based ports 5 AgingPeriod This setti...

Страница 77: ...ass functionality When checked the individual ports ditto setting determine whether RADIUS assigned QoS Class is enabled on that port When unchecked RADIUS server assigned QoS Class is disabled on all...

Страница 78: ...s mode the switch will send one EAPOL Success frame when the port link comes up and any client on the port will be allowed network access without authentication Force Unauthorized In this mode the swi...

Страница 79: ...once a supplicant is successfully authenticated on a port the whole port is opened for network traffic This allows other clients connected to the port for instance through a hub to piggy back on the s...

Страница 80: ...te the RADIUS server sends a success or failure indication which in turn causes the switch to open up or block traffic for that particular client using the Port Security module Only then will frames f...

Страница 81: ...e original VLAN ID which may be changed by the administrator in the meanwhile without affecting the RADIUSassigned This option is only available for single client modes i e Port based 802 1X Single 80...

Страница 82: ...st VLAN the port is considered authenticated and all attached clients on the port are allowed access on this VLAN The switch will not transmit an EAPOL Success frame when entering the Guest VLAN While...

Страница 83: ...enced in some way The ACLs are divided into Ether Types IPv4 ARP protocol MAC and VLAN parameters etc Here we will just go over the standard and extended access lists for TCP IP As you create ACEs for...

Страница 84: ...s Permit 4 Rate Limiter ID Select which rate limiter to apply on this port The allowed values are Disabled or the values 1 through 16 The default value is Disabled 5 Port Redirect Select which port fr...

Страница 85: ...uration of the ACL user module Disabled To close ports by changing the volatile port configuration of the ACL user module The default value is Enabled 10 Counter Counts the number of frames that match...

Страница 86: ...eter description 1 Rate Limiter ID The rate limiter ID for the settings contained in the same row 2 Rate The rate range is located 0 3276700 in pps Or 0 100 200 300 1000000 in kbps 3 Unit Specify the...

Страница 87: ...fined The maximum number of ACEs is 256 on each switch Click on the lowest plus sign to add a new ACE to the list The reserved ACEs used for internal protocol cannot be edited or deleted the order seq...

Страница 88: ...IPv4 frames which are not ICMP UDP TCP IPv6 The ACE will match all IPv6 standard frames 4 Action Indicates the forwarding action of the ACE Permit Frames matching the ACE may be forwarded and learned...

Страница 89: ...values Parameter description 1 Ingress Port Select the ingress port for which this ACE applies All The ACE applies to all port Port n The ACE applies to this port number where n is the number of the s...

Страница 90: ...matching the ACE are filtered 7 Rate Limiter Specify the rate limiter in number of base units The allowed range is 1 to 16 Disabled indicates that the rate limiter operation is disabled 8 Port Redirec...

Страница 91: ...a specific source MAC address The legal format is xx xx xx xx xx xx or xx xx xx xx xx xx or xxxxxxxxxxxx x is a hexadecimal digit A frame that hits this ACE matches this SMAC value 3 DMAC Filter Sele...

Страница 92: ...LAN Parameters 1 ARP RARP Specify the available ARP RARP opcode OP flag for this ACE Any No ARP RARP OP flag is specified OP is don t care ARP Frame must have ARP opcode set to ARP RARP Frame must hav...

Страница 93: ...you can enter a specific target IP mask in dotted decimal notation 9 ARP Sender MAC Match Specify the target IP filter for this specific ACE Specify whether frames can hit the action according to thei...

Страница 94: ...ify the Time to Live settings for this ACE zero IPv4 frames with a Time to Live field greater than zero must not be able to match this entry non zero IPv4 frames with a Time to Live field greater than...

Страница 95: ...ilter you can enter a specific DIP address in dotted decimal notation 11 DIP Mask When Network is selected for the destination IP filter you can enter a specific DIP mask in dotted decimal notation IP...

Страница 96: ...e bit then SIPv6 address 2001 2 and 2001 3 are applied to this rule 6 Hop Limit Specify the hop limit settings for this ACE zero IPv6 frames with a hop limit field greater than zero must not be able t...

Страница 97: ...e value 3 TCP UDP Source Range When Range is selected for the TCP UDP source filter you can enter a specific TCP UDP source range value The allowed range is 0 to 65535 A frame that hits this ACE match...

Страница 98: ...Specify the TCP Push Function PSH value for this ACE 0 TCP frames where the PSH field is set must not be able to match this entry 1 TCP frames where the PSH field is set must be able to match this ent...

Страница 99: ...revert to previously saved values Cancel Return to the previous page 4 5 2 4 IP Source Guard 4 5 2 4 1 Configuration The section describes to configure the IP Source Guard detail parameters of the swi...

Страница 100: ...ify IP Source Guard is enabled on which ports Only when both Global Mode and Port Mode on a given port are enabled IP Source Guard is enabled on this given port 3 Max Dynamic Clients Controls the unit...

Страница 101: ...the entry It will be deleted during the next save 2 Port The logical port for the settings 3 VLAN ID The vlan id for the settings 4 IP Address Allowed Source IP address 5 MAC Address Allowed Source MA...

Страница 102: ...on or disable the Global ARP Inspection 2 Port Mode Configuration Shows the scheduling mode for this port Specify ARP Inspection is enabled on which ports Only when both Global Mode and Port Mode on a...

Страница 103: ...ic Click to translate all dynamic entries to static entries 4 5 2 5 2 VLAN Configuration Each page shows up to 9999 entries from the VLAN table default being 20 selected through the entries per page i...

Страница 104: ...e configured on per VLAN setting Possible types are None Log nothing Deny Log denied entries Permit Log permitted entries ALL Log all entries Buttons Save Click to save changes Reset Click to undo any...

Страница 105: ...age will show the first 20 entries from the beginning of the Dynamic ARP Inspection Table The Start from port address VLAN MAC address and IP address input fields allow the user to select the starting...

Страница 106: ...ed the text No more entries is shown in the displayed table Use the button to start over 1 Port Switch Port Number for which the entries are displayed 2 VLAN ID VLAN ID in which the ARP traffic is per...

Страница 107: ...retransmitted to a server that is not responding If the server has not responded after the last retransmit it is considered to be dead 3 Deadtime Deadtime which can be set to a number between 0 to 144...

Страница 108: ...RADIUS Access Request packets If this field is left blank the NAS Identifier is not included in the packet Global Configuration 1 Delete To delete a RADIUS server entry check this box The entry will...

Страница 109: ...1000 to wait for a reply from a TACACS server before it is considered to be dead 2 Deadtime Deadtime which can be set to a number between 0 to 1440 minutes is the period during which the switch will n...

Страница 110: ...tion You can bundle more than one port with the same speed full duplex and the same MAC to be a single logical port thus the logical port aggregates the bandwidth of these ports This means you can app...

Страница 111: ...y saved values Parameter description Hash Code Contributors 1 Source MAC Address The Source MAC address can be used to calculate the destination port for the frame Check to enable the use of the Sourc...

Страница 112: ...aggregation and ports must be in the same speed in each group Buttons Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 6 2 LACP Aggregat...

Страница 113: ...Key value can participate in the same aggregation group while ports with different keys cannot 4 Role The Role shows the LACP activity status The Active will transmit LACP packets each second while Pa...

Страница 114: ...The port will be locked when it received the looping Proection frames If you want to resume the locked port please find out the looping path and take off the looping path then select the resume the lo...

Страница 115: ...8 Spanning Tree The Spanning Tree Protocol STP can be used to detect and disable network loops and to provide backup links between switches bridges or routers This allows the switch to interact with...

Страница 116: ...ridges to reconfigure the network to reestablish a valid network topology 4 8 1 Bridge Settings The section describes that how to configure the Spanning Tree Bridge and STP System settings It allows y...

Страница 117: ...is the priority of the CIST Otherwise this is the priority of the STP RSTP bridge 3 Forward Delay The delay used by STP Bridges to transit Root and Designated Ports to Forwarding used in STP compatib...

Страница 118: ...Timeout The time to pass before a port in the error disabled state can be enabled Valid values are between 30 and 86400 seconds 24 hours Buttons Save Click to save changes Reset Click to undo any cha...

Страница 119: ...en you need to click the Reset button It will revert to previously saved values Parameter description Configuration Identification 1 Configuration Name The MSTP RSTP STP protocol version setting Valid...

Страница 120: ...8 3 MATI Priorities When you implement a Spanning Tree protocol on the switch that the bridge instance The CIST is the default instance which is always active For controls the bridge priority Lower nu...

Страница 121: ...plement an Spanning Tree protocol on the switch that the bridge instance You need to configure the CIST Ports The section describes it allows the user to inspect the to inspect the current STP CIST po...

Страница 122: ...establishing the active topology of the network Lower path cost ports are chosen as forwarding ports in favour of higher path cost ports Valid values are in the range 1 to 200000000 4 Priority Contro...

Страница 123: ...rts If set it can cause temporary loss of connectivity after changes in a spanning tree s active topology as a result of persistently incorrect learned station location information It is set by a netw...

Страница 124: ...contains MSTI port settings for physical and aggregated ports Web Interface To configure the Spanning Tree MSTI Port Configuration parameters in the web interface 1 Click Configuration Spanning Tree M...

Страница 125: ...g ports in favour of higher path cost ports Valid values are in the range 1 to 200000000 3 Priority Controls the port priority This can be used to control priority of ports having identical port cost...

Страница 126: ...the description sentence 5 Rule When the profile is created click the edit button to enter the rule setting page of the designated profile Summary about the designated profile will be shown by clickin...

Страница 127: ...e Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved values Refresh Refreshes the displayed table starting from the input fields Updates the table s...

Страница 128: ...configure the Profile Table in the web interface 1 Click Configuration MVR Parameter description 1 MVR Mode Enable Disable the Global IPMC Profile Check to delete the entry 2 Delete Check to delete th...

Страница 129: ...ports are forbidden on source ports The default is Dynamic mode 7 Tagging Specify whether the traversed IGMP MLD control frames will be sent as Untagged or Tagged with MVR VID The default is Tagged 8...

Страница 130: ...function is used to establish the multicast groups to forward the multicast packet to the member ports and in nature avoids wasting the bandwidth while IP multicast packets are running over the netwo...

Страница 131: ...MP Snooping parameters in the web interface 1 Click Configuration IPMC IGMP Snooping Basic Configuration 2 Evoke to select enable or disable which Global configuration 3 Evoke which port wants to beco...

Страница 132: ...e Layer 3 multicast device or IGMP querier If an aggregation member port is selected as a router port the whole aggregation will act as a router port 7 Fast Leave Enable the fast leave on the port 8 T...

Страница 133: ...eted during the next save 2 VLAN ID The VLAN ID of the entry 3 IGMP Snooping Enabled Enable the per VLAN IGMP Snooping Up to 32 VLANs can be selected for IGMP Snooping 4 Querier Election Enable to joi...

Страница 134: ...into the periodic General Queries The allowed range is 0 to 31744 in tenths of seconds default query response interval is 100 in tenths of seconds 10 seconds 11 LLQI LMQI for IGMP Last Member Query I...

Страница 135: ...ch ports An IGMP profile can contain one or more multicast groups and specifies whether access to the group is permitted or denied If an IGMP profile denying access to a multicast group is applied to...

Страница 136: ...k to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 11 2 MLD Snooping 4 11 2 1 Basic Configuration This page provides MLD Snooping related configurat...

Страница 137: ...abled unregistered IPMCv6 traffic flooding is always active in spite of this setting 3 MLD SSM Range SSM Source Specific Multicast Range allows the SSM aware hosts and routers run the SSM service mode...

Страница 138: ...age input field When first visited the web page will show the first 20 entries from the beginning of the VLAN Table The first displayed will be the one with the lowest VLAN ID found in the VLAN Table...

Страница 139: ...7 RV Robustness Variable The Robustness Variable allows tuning for the expected packet loss on a network The allowed range is 1 to 255 default robustness variable value is 2 8 QI Query Interval The Q...

Страница 140: ...nments as like the metropolitan or multiple dwelling unit MDU installations an user might want to control the multicast groups to which a user on a switch port can belong It allows the user to control...

Страница 141: ...d with the designated profile Buttons Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 12 LLDP The switch supports the LLDP For current i...

Страница 142: ...configure the LLDP in the web interface 1 Click Configuration LLDP 2 Modify LLDP timing parameters 3 Set the required mode for transmitting or receiving LLDP messages 4 Specify the information to inc...

Страница 143: ...to 1 10 seconds LLDP Port Configuration 1 Port The switch port number of the logical LLDP port 2 Mode Select LLDP mode Rx only The switch will not send out LLDP information but LLDP information from...

Страница 144: ...ormation transmitted 5 Sys Name Optional TLV When checked the system name is included in LLDP information transmitted 6 Sys Descr Optional TLV When checked the system description is included in LLDP i...

Страница 145: ...ult is 4 3 Modify Coordinates Location parameters 4 Fill Civic Address Location parameters 5 Add new policy 6 Click Apply will show following Policy Port Configuration 7 Select Policy ID for each port...

Страница 146: ...to specify the number of times the fast start transmission would be repeated The recommended value is 4 times given that 4 LLDP frames with a 1 second interval will be transmitted when an LLDP frame...

Страница 147: ...Code 4269 Prime Meridian Name Greenwich The associated vertical datum is Mean Lower Low Water MLLW This datum pair is to be used when referencing locations on water sea ocean Coordinates Location 1 C...

Страница 148: ...ame residence and office occupant Example Flemming Jahn 16 Zip code Postal zip code Example 2791 17 Building Building structure Example Low Library 18 Apartment Unit Apartment suite Example Apt 42 19...

Страница 149: ...nces supporting interactive voice services 4 Guest Voice Signalling conditional for use in network topologies that require a different policy for the guest voice signalling than for the guest voice me...

Страница 150: ...the Layer 2 priority to be used for the specified application type L2 Priority may specify one of eight priority levels 0 through 7 as defined by IEEE 802 1D 2004 A value of 0 represents use of the d...

Страница 151: ...hones 4 13 1 PoE This page allows the user to inspect and configure the current PoE port settings and show all PoE Supply Web Interface To configure Power Over Ethernet in the web interface 1 Click co...

Страница 152: ...ual power consumption for all ports exceeds the amount of power that the power supply can deliver or if the actual power consumption for a given port exceeds the reserved power for that port The ports...

Страница 153: ...iority The priority is used in the case where the remote devices require more power than the power supply can deliver In this case the port with the lowest priority will be turn off starting from the...

Страница 154: ...llows the user to make a perfect schedule of PoE power supply PoE Scheduling not only makes PoE management easier but also saves more energy Web Interface To Display Power Over Ethernet Scheduler in t...

Страница 155: ...ay Each interval have 30 minutes 2 Day The current scheduling state is displayed graphically during the week Green indicates the power is on and red that it is off Directly changes checkmarks to indic...

Страница 156: ...ing of frames is based upon the DMAC address contained in the frame The switch builds up a table that maps MAC addresses to switch ports for knowing which ports the frames should go to based upon the...

Страница 157: ...Aging Time 3 Click Apply MAC Table Learning 1 Click configuration 2 Specify the Port Members Auto Disable Secure 3 Click Apply Static MAC Table Configuration 1 Click configuration and Add new Static...

Страница 158: ...ule is the MAC Based Authentication under 802 1X Each port can do learning based upon the following settings 1 Auto Learning is done automatically as soon as a frame with unknown SMAC is received 2 Di...

Страница 159: ...ecific VLAN for management purpose The management VLAN is used to establish an IP connection to the switch from a workstation connected to a port in the VLAN This connection supports a VSM SNMP and Te...

Страница 160: ...13 200 300 Spaces are allowed in between the delimiters 2 Ethertype for Custom Sports This field specifies the ethertype TPID specified in hexadecimal used for Custom Sports The setting is in force f...

Страница 161: ...only tagged frames are accepted on ingress Hybrid Hybrid ports resemble trunk ports in many ways but adds additional port configuration features In addition to the characteristics described for trunk...

Страница 162: ...ress Filtering Hybrid ports allow for changing ingress filtering Access and Trunk ports always have ingress filtering enabled If ingress filtering is enabled checkbox is checked frames classified to a...

Страница 163: ...all possible VLANs Buttons Apply Click to save changes Reset Click to undo any changes made locally and revert to previously saved values 4 16 Private VLANs The VLAN membership configuration for the...

Страница 164: ...gured as needed Legal values for a VLAN ID are 1 through 4095 The VLAN is enabled on the selected stack switch unit when you click on Save The VLAN is thereafter present on the other stack switch unit...

Страница 165: ...t to the forwarding map generated based upon whether the ingress port was configured as a protected or non protected port This page is used for enabling or disabling port isolation on ports in a Priva...

Страница 166: ...s the network As a result it will not be able to use the resources in the old VLAN On the other hand if Port A and Port B belong to the same VLAN after terminal devices access the network through Port...

Страница 167: ...o undo any changes made locally and revert to previously saved values Updates the table starting from the first entry in the MAC based VLAN Table Updates the table starting with the entry after the la...

Страница 168: ...C SNAP Note On changing the Frame type field valid value of the following text field will vary depending on the new frame type you selected 3 Value Valid value that can be entered in this text field d...

Страница 169: ...atic refresh occurs every 3 seconds Refresh Click to refresh the page immediately Add New Entry Click to add a new entry in mapping table Save Click to save changes Reset Click to undo any changes mad...

Страница 170: ...can be used to undo the addition of new entry Button Auto Refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refresh Click to refresh the page immediate...

Страница 171: ...existing entries 6 Port Member A row of check boxes for each port is displayed for each IP subnet based VLAN entry To include a port in a IP subnet based VLAN check the box To remove or exclude the po...

Страница 172: ...re enables voice traffic forwarding on the Voice VLAN then the switch can classify and schedule network traffic It is recommended that there be two VLANs on a port one for voice one for data Before co...

Страница 173: ...the Voice VLAN traffic class All traffic on the Voice VLAN will apply this class 5 Port Mode Indicates the Voice VLAN port mode Possible port modes are Disabled Disjoin from Voice VLAN Auto Enable aut...

Страница 174: ...interface 1 Select Add new entry Delete in the Voice VLAN OUI table 2 Specify Telephony OUI Description 3 Click Save Parameter description 1 Delete Check to delete the entry It will be deleted during...

Страница 175: ...to the frame according to what was configured for that specific QoS class The switch support advanced memory control mechanisms providing excellent performance of all QoS classes under any traffic sc...

Страница 176: ...uled by a QCL entry Note If the default CoS has been dynamically changed then the actual default CoS is shown in parentheses after the configured default CoS 3 DPL Controls the default drop precedence...

Страница 177: ...P Based Click to Enable DSCP Based QoS Ingress Port Classification 8 Address Mode The IP MAC address mode specifying whether the QCL classification must be based on source SMAC SIP or destination DMAC...

Страница 178: ...3300 when the Unit is Mbps or kfps 4 Unit Controls the unit of measure for the policer rate as kbps Mbps fps or kfps The default value is kbps 5 Flow Control If flow control is enabled and the port is...

Страница 179: ...port number in order to configure the schedulers 2 Mode Shows the scheduling mode for this port 3 Qn Shows the weight for this queue and port 4 19 4 Port Shaping This section provides an overview of Q...

Страница 180: ...ers 2 Qn Shows disabled or actual queue shaper rate e g 800 Mbps 3 Port Shows disabled or actual port shaper rate e g 800 Mbps 4 19 5 Port Tag Remarking The Section provides user to get an overview of...

Страница 181: ...to configure the basic QoS Port DSCP Configuration settings for all switch ports Others the settings relate to the currently selected stack unit as reflected by the page header Web Interface To confi...

Страница 182: ...ick the checkbox 4 Classify Classification for a port have 4 different values Disable No Ingress DSCP Classification DSCP 0 Classify if incoming or translated if enabled DSCP is 0 Selected Classify on...

Страница 183: ...es made locally and revert to previously saved values 4 19 7 DSCP Based QoS The section will teach user to configure the DSCP Based QoS mode that This page allows you to configure the basic QoS DSCP b...

Страница 184: ...5 Web Management Monitor of IGR 842POE 179 AirLive IGR 842POE User Manual...

Страница 185: ...5 Web Management Monitor of IGR 842POE AirLive IGR 842POE User Manual 180...

Страница 186: ...81 AirLive IGR 842POE User Manual Parameter description 1 DSCP Maximum number of support ed DSCP values are 64 2 Trust Click to check if the DSCP value is trusted 3 QoS Class QoS Class value can be an...

Страница 187: ...llows you to map DSCP value to a QoS Class and DPL value Others the settings relate to the currently selected stack unit as reflected by the page header Web Interface To configure the DSCP Classificat...

Страница 188: ...5 Web Management Monitor of IGR 842POE 183 AirLive IGR 842POE User Manual...

Страница 189: ...5 Web Management Monitor of IGR 842POE AirLive IGR 842POE User Manual 184...

Страница 190: ...e two configuration parameters for DSCP Translation Translate Classify 3 Translation DSCP at Ingress side can be translated to any of 0 63 DSCP values 4 Classify Click to enable Classification at Ingr...

Страница 191: ...The section describes to teach user to configure and allows you to map DSCP value to a QoS Class and DPL value Others the settings relate to the currently selected stack unit as reflected by the page...

Страница 192: ...ol List QCL which is made up of the QCEs Each row describes a QCE that is defined The maximum number of QCEs is 256 on each switch Click on the lowest plus sign to add a new QCE to the list Web Interf...

Страница 193: ...Possible values are Any Match any DMAC Unicast Match unicast DMAC Multicast Match multicast DMAC Broadcast Match broadcast DMAC The default value is Any 4 SMAC Match specific source MAC address or An...

Страница 194: ...with the frame s content Possible actions are CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classify DSCP value 11 Modification Select the classified DSCP value 0 63 You can mo...

Страница 195: ...55 When Mask is converted to a 32 bit binary string and read from left to right all bits following the first zero must also be zero If a port is configured to match on DMAC DIP this field is the Desti...

Страница 196: ...e switch Web Interface To configure the Storm Control Configuration parameters in the web interface 1 Click Configuration QoS Storm Control Configuration 2 Evoke to select the frame type to enable sto...

Страница 197: ...d by Port B will be copied to Port A for monitoring Web Interface To configure the Mirror in the web interface 1 Click Configuration Mirroring 2 Scroll to select Port to mirror on which port 3 Scroll...

Страница 198: ...s Because of this mode for the selected mirror port is limited to Disabled or Rx only Button Save Click to save changes Reset Click to undo any changes made locally and revert to previously saved valu...

Страница 199: ...default is 60 LeaveAll time is a value in the range 1000 5000 in the units of centi seconds i e in units of one hundredth of a second The default is 1000 2 Max number of VLANs The logical port for the...

Страница 200: ...ms It serves as a unique key that will identify this agent over extended periods of time Both IPv4 and IPv6 addresses are supported Agent Configuration 1 Owner The logical port for the settings contai...

Страница 201: ...sted the switch will automatically adjust it to the closest achievable This will be reported back in this field 4 Flow Sample Max Header Save Click to save changes The maximum number of bytes that sho...

Страница 202: ...g Group 3 Index 3 It supports configuration of chain and balancing chain 2 Mode Enable Ring on the specific group When Group 1 or 2 is enabled all configuration of Group 3 will be reset to default Gro...

Страница 203: ...ts are forward port When role is coupling primary only need one ring port named primary port When role is coupling backup only need one ring port named backup port This backup port is redundant port i...

Страница 204: ...y Reset Click to undo any changes made locally and revert to previously saved values 4 24 DDMI Configure DDMI on this page Web Interface To configure the DDMI in the web interface 1 Click Configuratio...

Страница 205: ...guring the contact information name and location of the switch Web Interface To configure System Information in the web interface 1 Click Monitor System and Information 2 Check the contact information...

Страница 206: ...Refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refresh Click to refresh the page 5 1 2 CPU Load This page displays the CPU load using line chart The...

Страница 207: ...RP cache status Web Interface To configure IP Status in the web interface 1 Click Monitor System and IP Status Parameter description IP Interfaces 1 Interface The name of the interface 2 Type The addr...

Страница 208: ...log entries will be cleared To clear specific system log entries select the clear level first then click the Clear button The Start from ID input field allow the user to change the starting point in...

Страница 209: ...the selected entries Updates the table entries starting from the first available entry Updates the table entries ending at the last entry currently displayed Updates the table entries starting from t...

Страница 210: ...sh the page 5 2 Green Ethernet 5 2 1 Port Power Savings A set of enhancements to the twisted pair and backplane Ethernet family of computer networking standards that allow for less power consumption d...

Страница 211: ...tly saving power due to EEE When EEE is enabled the system will powered down if no frame has been received or transmitted in 5 uSec 6 Actiphy Saving Shows if the system is currently saving power due t...

Страница 212: ...ds Refresh Click to refresh the page 5 3 2 Trafice Overview This page provides an overview of general traffic statistics for all switch ports Web interface To configure Trafice Overview in the web int...

Страница 213: ...lly Automatic refresh occurs every 3 seconds Refresh Click to refresh the page Clear Clears the counters for all ports 5 3 3 QoS Statistics This page provides statistics for the different queues for a...

Страница 214: ...escription 1 User The logical port for the settings contained in the same row 2 QCE There are 8 QoS queues per port Q0 is the lowest priority queue 3 Port Indicates the list of ports configured with t...

Страница 215: ...o Refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Resolve Conflict Click to release the resources required to add QCL entry in case the conflict statu...

Страница 216: ...peration Receive and Transmit Size Counters The number of received and transmitted good and bad packets split into categories based on their respective frame sizes Receive and Transmit Queue Counters...

Страница 217: ...ge immediately Auto Refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Clear Click to refresh the page immediately 5 4 DHCP The section describes to conf...

Страница 218: ...eclined IP addresses Binding Counters 1 Automatic Binding Number of bindings with network type pools 2 Manual Binding Number of bindings that administrator assigns an IP address to a client That is th...

Страница 219: ...REQUEST messages received 3 NAK Number of DHCP DECLINE messages received Button Refresh Click to refresh the page immediately Auto Refresh Check this box to refresh the page automatically Automatic re...

Страница 220: ...eclined IP This page displays declined IP addresses Web interface To configure Detailed Statistics in the web interface 1 Click Monitor DHCP Sever and Declined IP Parameter description 1 Declined IP L...

Страница 221: ...description 1 MAC Address User MAC address of the entry 2 VLAN ID VLAN ID in which the DHCP traffic is permitted 3 Source Port Switch Port Number for which the entries are displayed 4 IP Address User...

Страница 222: ...sing Circuit ID The number of packets received with the Circuit ID option missing 6 Receive Missing Remote ID The number of packets received with the Remote ID option missing 7 Receive Bad Circuit ID...

Страница 223: ...ed if the incoming DHCP packet is done by L3 forwarding mechanism And clear the statistics on specific port may not take effect on global statistics since it gathers the different layer overview Web i...

Страница 224: ...on 53 with value 12 packets received and transmitted 12 Rx and Tx Active The number of lease active option 53 with value 13 packets received and transmitted 13 Rx Discarded checksum error The number o...

Страница 225: ...1 1 Switch This page shows the Port Security status Port Security is a module with no direct configuration Configuration comes indirectly from other modules the user modules When a user module has ena...

Страница 226: ...us Shows the current state of the port It can take one of four values Disabled No user modules are currently using the Port Security service Ready The Port Security service is in use by at least one u...

Страница 227: ...forward If only one chooses to block it it will be blocked until that user module decides otherwise Web interface To configure Security in the web interface 1 Click Monitor Security Network Port Secu...

Страница 228: ...ate The port s current administrative state Refer to NAS Admin State for a description of possible values 3 Port State The current state of the port Refer to NAS Port State for a description of the in...

Страница 229: ...ed backend server RADIUS Authentication Server statistics only Use the port select box to select which port details to be displayed Web interface To configure Security in the web interface 1 Click Mon...

Страница 230: ...Read more about RADIUS assigned VLANs here If the port is moved to the Guest VLAN Guest is appended to the VLAN ID Read more about Guest VLANs her 4 Last Supplicant Client Info Information about the l...

Страница 231: ...authenticated state it is allowed to forward frames on the port and in the unauthenticated state it is blocked As long as the backend server hasn t successfully authenticated the client it is unauthe...

Страница 232: ...pe based ACE will not get matched by IP and ARP frames ARP The ACE will match ARP RARP frames IPv4 The ACE will match all IPv4 frames IPv4 ICMP The ACE will match IPv4 frames with ICMP protocol IPv4 U...

Страница 233: ...shows up to 99 entries from the Dynamic ARP Inspection table default being 20 selected through the entries per page input field When first visited the web page will show the first 20 entries from the...

Страница 234: ...Guard table default being 20 selected through the entries per page input field When first visited the web page will show the first 20 entries from the beginning of the Dynamic IP Source Guard Table T...

Страница 235: ...able starting from the input fields Clear Flush all dynamic entries Update the table starting from the first entry in the Dynamic IP Source Guard Table Updates the table starting with the entry after...

Страница 236: ...to navigate to detailed statistics for this server 2 IP Address The IP address and UDP port number in IP Address UDP Port notation of this server 3 Status The current status of the server This field...

Страница 237: ...ver and the latest roundtrip time RADIUS Accounting Statistics 1 Packet Counter RADIUS accounting server packet counter There are five receive and four transmit counters 2 Other Info This section cont...

Страница 238: ...op The total number of events in which packets were dropped by the probe due to lack of resources 4 Octets The total number of octets of data including those in bad packets received on the network 5 P...

Страница 239: ...between 256 to 511 octets in length 18 512 1023 The total number of packets including bad packets received that were between 512 to 1023 octets in length 19 1024 1588 The total number of packets incl...

Страница 240: ...in bad packets received on the network 6 Pkts The total number of packets including bad packets broadcast packets and multicast packets received 7 Broadcast The total number of good packets received...

Страница 241: ...table i e the entry with the lowest History Index and Sample Index Updates the table starting with the entry after the last entry currently displayed 5 5 4 1 3 Alarm This page provides an overview of...

Страница 242: ...Refresh Click to refresh the page immediately Updates the table starting from the first entry in the Alarm Table i e the entry with the lowest ID Updates the table starting with the entry after the l...

Страница 243: ...entry after the last entry currently displayed 5 6 LACP 5 6 1 System Status This section describes that when you complete to set LACP function on the switch then it provides a status overview for all...

Страница 244: ...LACP Port Status 2 If you want to auto refresh the information then you need to evoke the Auto refresh 3 Click Refresh to refresh the LACP Port Status Parameter description 1 Port The switch port num...

Страница 245: ...o refresh 3 Click Refresh to refresh the LACP Port Statistics Parameter description 1 Port The switch port number 2 LACP Yes means that LACP is enabled and the port link is up No means that LACP is no...

Страница 246: ...currently configured port action 3 Transmit The currently configured port transmit mode 4 Loops The number of loops detected on this port 5 Status The current loop protection status of the port 6 Loo...

Страница 247: ...etailed Bridge Status 2 Bridge ID The Bridge ID of this Bridge instance 3 Root ID The Bridge ID of the currently elected root bridge 4 Root Port The switch port currently assigned the root port role 5...

Страница 248: ...ort The port state can be one of the following values Discarding Learning Forwarding 4 Uptime The time since the bridge port was last initialized Button Refresh Click to refresh the page immediately A...

Страница 249: ...te of the Topology Change Flag of this Bridge instance 7 Discarded Illegal The time since last Topology Change occurred Button Refresh Click to refresh the page immediately Clear Click to reset the co...

Страница 250: ...to reset the counters 5 9 2 MVR Channel Groups Each page shows up to 99 entries from the MVR Group table default being 20 selected through the entries per page input field When first visited the web...

Страница 251: ...default being 20 selected through the entries per page input field When first visited the web page will show the first 20 entries from the beginning of the MVR SFM Information Table The Start from VL...

Страница 252: ...destined to the specific group address from the source IPv4 IPv6 address could be handled by chip or not Button Auto Refresh Check this box to refresh the page automatically Automatic refresh occurs e...

Страница 253: ...multicast group that had not been built up in advance IGMP mode enables the switch to issue IGMP function that you enable IGMP proxy or snooping on the switch which connects to a router closer to the...

Страница 254: ...s every 3 seconds Refresh Click to refresh the page immediately Clear Click to reset the counters 5 10 1 2 Groups Information After you complete to set the IGMP Snooping function then you could let th...

Страница 255: ...e starting from the input fields Updates the table starting from the first entry in the IGMP Group Table Updates the table starting with the entry after the last entry currently displayed 5 10 1 3 IPv...

Страница 256: ...t can be either Include or Exclude 5 Source Address IP Address of the source Currently system limits the total number of IP source addresses for filtering to be 128 6 Type Indicates the Type It can be...

Страница 257: ...1 VLAN ID The VLAN ID of the entry 2 Querier Version Working Querier Version currently 3 Host Version Working Host Version currently 4 Querier Status Shows the Querier status is ACTIVE or IDLE DISABLE...

Страница 258: ...entries per page input field When first visited the web page will show the first 20 entries from the beginning of the MLD Group Table The Start from VLAN and group input fields allow the user to sele...

Страница 259: ...and group input fields allow the user to select the starting point in the MLD SFM Information Table Clicking the Refresh button will update the displayed table starting from that or the closest next M...

Страница 260: ...1 LLDP The switch supports the LLDP For current information on your switch model The Link Layer Discovery Protocol LLDP provides a standards based method for enabling switches to advertise themselves...

Страница 261: ...System Capabilities describes the neighbor unit s capabilities The possible capabilities are 1 Other 2 Repeater 3 Bridge 4 WLAN Access Point 5 Router 6 Telephone 7 DOCSIS cable device 8 Station only 9...

Страница 262: ...nd Endpoint Devices LLDP MED Network Connectivity Device Definition LLDP MED Network Connectivity Devices as defined in TIA 1057 provide access to the IEEE 802 based LAN infrastructure for LLDP MED En...

Страница 263: ...roducts that have IP media capabilities however may or may not be associated with a particular end user Capabilities include all of the capabilities defined for the previous Generic Endpoint Class Cla...

Страница 264: ...ling than for the guest voice media 5 Softphone Voice for use by softphone applications on typical data centric devices such as PCs or laptops 6 Video Conferencing for use by dedicated Video Conferenc...

Страница 265: ...gotiation is currently enabled at the link partner If Auto negotiation is supported and Auto negotiation status is disabled the 802 3 PMD operating mode will be determined the operational MAU type fie...

Страница 266: ...ues shall be defined as the local link partners reflection echo of the remote link partners respective values When a local link partner receives its echoed values from the remote link partner it can d...

Страница 267: ...or LLDP Port Statistics 2 If you want to auto refresh the information then you need to evoke the Auto refresh 3 Click Refresh to refresh the LLDP Port Statistics Parameter description Global Counters...

Страница 268: ...Entries are removed from the table when a given port s link is down an LLDP shutdown frame is received or when the entry ages out 6 TLVs Discarded Shows the number of new entries added since switch r...

Страница 269: ...ccording to a class that defines the maximum power the PD will use The PD Class shows the PDs class Five Classes are defined Class 0 Max power 15 4 W Class 1 Max power 4 0 W Class 2 Max power 7 0 W Cl...

Страница 270: ...the MAC table default being 20 selected through the entries per page input field When first visited the web page will show the first 20 entries from the beginning of the MAC Table The first displayed...

Страница 271: ...in the MAC Table i e the entry with the lowest VLAN ID and MAC address Updates the table starting with the entry after the last entry currently displayed 5 14 VLANs To assign a specific VLAN for mana...

Страница 272: ...Membership Parameter description 1 VLAN User Various internal software modules may use VLAN services to configure VLAN memberships on the fly The drop down list on the right allows for selecting betw...

Страница 273: ...ftware modules hasn t overridden any of the port settings the text No data exists for the selected user is shown in the table 2 Port The logical port for the settings contained in the same row 3 Port...

Страница 274: ...e displayed as Yes for the Combined user and the offending software module The Combined user reflects what is actually configured in hardware Button Combined Select VLAN Users from this drop down list...

Страница 275: ...w 2 If you want to auto refresh the information then you need to evoke the Auto refresh 3 Click Refresh to refresh the sFlow Parameter description Receiver Statistics 1 Owner This field shows the curr...

Страница 276: ...or which the following statistics applies 2 Rx and Tx Flow Samples The number of flow samples sent to the sFlow receiver originating from this port Here flow samples are divided into Rx and Tx flow sa...

Страница 277: ...ole 4 State When ring is complete it will show Normal When ring is incomplete at least one link is down it will show Fail 5 Ring Port s Describes current status of ring port s Button Auto Refresh Chec...

Страница 278: ...sion level for part number provided by vendor 6 Date Code Indicates Date code Vendor s manufacturing date code 7 Transceiver Indicates Transceiver compatibility 5 18 2 Detailed Display DDMI detailed i...

Страница 279: ...ent The current value of temperature voltage TX bias TX power and RX power 2 High Alarm Threshold The high alarm threshold value of temperature voltage TX bias TX power and RX power 3 High Warn Thresh...

Страница 280: ...ity issues Web interface To configure Ping in the web interface 1 Click Diagnostics Ping Parameter description 1 IP Address The destination IP Address 2 Ping Length The payload size of the ICMP packet...

Страница 281: ...not given PING6 finds the best match interface for destination Do not specify egress interface for loopback address Do specify egress interface for link local or multicast address Button Start Click...

Страница 282: ...tion Do not specify egress interface for loopback address Do specify egress interface for link local or multicast address Button Start Click to start transmitting ICMP packets New Ping Click to re sta...

Страница 283: ...nated pair Open Open pair Short Shorted pair Short A Cross pair short to pair A Short B Cross pair short to pair B Short C Cross pair short to pair C Short D Cross pair short to pair D Cross A Abnorma...

Страница 284: ...e web interface 1 Click Maintenance Restart Device Parameter description Button Yes Click to restart device No Click to return to the Port State page without restarting 7 2 Factory Default You can res...

Страница 285: ...rameter description Button Browse Go to find the software image and click Upload Upload After finding the software image click the button to update firmware After the software image is uploaded a page...

Страница 286: ...manual intervention uploading a new firmware image to the device will automatically use the primary image slot and activate this 3 The firmware version and date information may be empty for older firm...

Страница 287: ...e Configuration and Save startup config 7 4 2 Download It is possible to download any of the files on the switch to the web browser Select the file and click Download Configuration Download running co...

Страница 288: ...three system files mentioned above plus two other files it is not possible to create new files but an existing file must be overwritten or another deleted first Web interface To configure Configuratio...

Страница 289: ...ete any of the writable files stored in flash including startup config If this is done and the switch is rebooted without a prior Save operation this effectively resets the switch to default configura...

Страница 290: ...ollisions and other network problem and can seriously impair network performance A category 5e cable tester is a recommended tool for every 1000Base T network installation Improper Network Topologies...

Страница 291: ...abit 1000T IEEE802 3x Flow Control and Back pressure IEEE802 1d Spanning tree protocol IEEE802 1w Rapid Spanning tree protocol IEEE802 1s Multicast Spanning Tree Protocol IEEE802 1p Class of service I...

Страница 292: ...e MIB RFC 1493 RMON MIB RFC 1757 statistics Ethernet like MIB RFC 1643 Enterprise MIB SNMP Trap Port Trunk Support IEEE802 3ad with LACP function Static aggregation Supports IEEE802 1d STP IEEE802 1w...

Страница 293: ...sification and re marking ACLs trusted QoS IPv6 Applications QoS Supports IGMP v1 v2 snooping Supports IGMP Querier Support Port Mirroring Supports 802 1x Radius TACACS Support Access Control List Tem...

Страница 294: ...Cat 5 UTP STP cable The 100Base TX standard is backward compatible with the 10Mbps 10 BaseT standard 1000Base SX Also known as 802 3z The IEEE standard defines how to transmit gigabit Ethernet data u...

Страница 295: ...Each packet carries a VLAN ID called Tag as it traveled across the network Therefore the VLAN configuration can be configured across multiple switches In 802 1Q spec possible 4096 VLAN ID can be crea...

Страница 296: ...IP multicast memberships to neighboring multicast switches and routers IGMP Snooping is a feature that allows an Ethernet Switch to listen in on the IGMP conversation between hosts and routers When I...

Страница 297: ...only the devices with the approved MAC address can connect with the network Mbps Megabits Per Second One million bits per second a unit of measurement for data transmission MiniGBIC A type of Gigabit...

Страница 298: ...l with the functionality of a very basic form of FTP It is used to transfer small amounts of data between hosts on a network such as Switch firmware The switch port can auto detect straight or crossov...

Страница 299: ...here should be only one active cabling path at any time Data path loops will cause broadcast storms that will severely impact your network performance 10 1 Cabling RJ 45 ports use unshielded twisted p...

Отзывы: