Puesta en servicio
Puesta fuera de servicio
Startup
Shutdown
7
20
.04.
2000
USA
ES
1.
Check that all screw and flange con-
nections are screwed down.
2.
Valve
A
and
B
are closed.
SLOWLY
Open valve
C
.
3.
Slowly open valve
A
.
4.
After the pressure gauge shows opera-
ting pressure, slowly open
valve
B
.
5.
Close valve
C
.
The unit can now be placed into regular
operation.
7.2 Shutdown
The following steps are essential when
shutting down the unit:
1.
Open
valve
C
.
2.
Slowly close valve
A
and
B
.
7.3 Depressurising the Unit
The unit can be depressurised by closing the
valves
A
and
C
. Wait until the pipelines be-
hind the unit are depressuri
z
ed.
If
only the
AKC
should b
e
depressuri
z
ed, please install a separate valve
for depressuri
z
ing.
1.
Comprobar que todas las uniones
roscadas y bridadas estén apretadas.
2.
Las válvulas
A
y
B
permanecen
cerradas. Abrir la válvula
C
.
3.
Abrir lentamente la válvula
A
.
4.
Abrir lentamente la válvula
B
en el
momento en que el manómetro indique
la presión de trabajo de la instalación.
5.
Cerrar la válvula
C
.
De esta forma la instalación ha sido puesta
en funcionamiento correctamente y puede
comenzar su trabajo regular.
7.2 Puesta fuera de servicio
Ejecutar los siguientes pasos para desconec-
tar el funcionamiento de la instalación:
1.
Abrir la válvula
C
.
2.
Cerrar lentamente las válvulas
A
y
B
.
7.3 Descarga de la presión en el
equipo
Se puede descargar la presión de la
instalación al cerrar las válvulas
A
y
C
.
Esperar hasta que los conductos de tubo
detrás de la instalación hayan sido
descargados de presión.
Si se quiere descargar de presión
únicamente el
AKC
, hay que
instalar
una válvula aparte para descargar
dicha
presión.