SWIR Area Camera Series User’s Manual
(OM170000021A)
- 54 -
8.10.
DigitalIOControl
In the DigitalIOControl, the settings of the input, GPI and output, GPO(0) and GPO(1) are possible.
In the DigitalIOControl, the name for input and output are called as the followings.
GPI
:
Line0
GPO[0]
:
Line1
GPO[1]
:
Line2
In order to access to each line and CC, the LineSelctor should be set according the following commands.
command
param1
Setting
CL line-selector
0
Line0
1
Line1
2
Line2
12
CC1
13
CC2
14
CC3
15
CC4
GV LineSelector
Line0
Line1
Line2
8.10.1.
Line0(CC1,2,3,4)
Line0 is connected GPIO circuits and the signal for input only.
Refer chapter 6.3.1
In the CameraLink interface, CC1 to CC4 are used for the input signal.
In order to recognize the current signal level, execute the following command.
command
param1
Value
CL line-status
0
Negate
1
Assert
GV LineStatus
false
Negate
true
Assert
If the level of the signal needs to be reversed, execute the following command.
command
param1
Setting
CL
line-inverter
0
Non inverted
1
Inverted
GV LineInverter
false
Non inverted
true
Inverted
Содержание ABA-001IR
Страница 1: ...SWIR Camera Series ABA 003IR ABA 001IR User s Manual...
Страница 73: ...SWIR Area Camera Series User s Manual OM170000021A 73 10 3 Outlook dimensions 10 3 1 ABA 003IR GE...
Страница 74: ...SWIR Area Camera Series User s Manual OM170000021A 74 10 3 2 ABA 003IR CL...
Страница 75: ...SWIR Area Camera Series User s Manual OM170000021A 75 10 3 3 ABA 001IR GE...
Страница 76: ...SWIR Area Camera Series User s Manual OM170000021A 76 10 3 4 ABA 001IR CL...
Страница 77: ...SWIR Area Camera Series User s Manual OM170000021A 77 10 4 EU Declaration of Conformity...