8.9.
Trigger setting example and its timing
8.9.1.
ExposureMode = Timed (Free-running)
This mode does not require the trigger signal and continuously exposes and outputs the image after the
exposure is activated. The horizontal and vertical timing are generated in the camera. In this
free-running mode, the capturing timing is not controlled. The exposure time and frame rate can be set.
Setting
command
param1
Features
CL
exp-mode
0
ExposureMode
trg-selector
0
AcquisitionStart
trg-mode
0
trg-selector
1
AcquisitionEnd
trg-mode
0
trg-selector
2
AcquisitionActive
trg-mode
0
trg-selector
12
ExposureActive
trg-mode
0
GV
ExposureMode
ExposureMode
TriggerSelector
AcqusitionStart
TriggerMode
Off
TriggerSelector
AcqusitionEnd
TriggerMode
Off
TriggerSelector
AcqusitionActive
TriggerMode
Off
TriggerSelector
ExposureActive
TriggerMode
Off
Timing
2H
1H(31.36us)
512H
32.22us
FrameRate
※
Exposure
※
ExposureActive
Sensor Exposure
Sensor Readout
Image processing
ROI circuit
Output
(CL transmitter input)
FrameRate
:
1/AcquisitionFrameRate
Exposure
:
ExposureTime
18.68us
0.02us
Total:
113.64us
32.22us
Содержание ABA-001IR
Страница 1: ...SWIR Camera Series ABA 003IR ABA 001IR User s Manual...
Страница 73: ...SWIR Area Camera Series User s Manual OM170000021A 73 10 3 Outlook dimensions 10 3 1 ABA 003IR GE...
Страница 74: ...SWIR Area Camera Series User s Manual OM170000021A 74 10 3 2 ABA 003IR CL...
Страница 75: ...SWIR Area Camera Series User s Manual OM170000021A 75 10 3 3 ABA 001IR GE...
Страница 76: ...SWIR Area Camera Series User s Manual OM170000021A 76 10 3 4 ABA 001IR CL...
Страница 77: ...SWIR Area Camera Series User s Manual OM170000021A 77 10 4 EU Declaration of Conformity...