AGRU SP 63-M Скачать руководство пользователя страница 23

Version October 2014

24 

EN

agru SP 63-mobile User’s Manual

5.1 

Downloading Welding Reports to a USB Stick

When a USB stick is inserted into the interface port while the default 
screen (see Display 3) is showing, the machine displays the menu in 
which the file type can be selected that is going to be used for download-
ing the reports (Display 21).

After the selection of the file format for download, a similar screen ap-
pears and offers five options of what exactly will be downloaded:

all reports in memory (i. e., since the reports were last deleted)

the reports that belong to a certain commission or project

the reports of operations performed by a certain welder

all reports in a certain range of dates

all reports in a certain range of reports/report numbers

When an option that does not send all, but only a selection of reports to 
the stick was selected, the operator has to define the desired selection/
restriction on the next screen. If a commission number or welder is to be 
selected, reading it from a transponder card or a bar code is also possible. 
With these two restrictions, he can browse through the reports in system 
memory to select the desired commission (see Display 20) or desired 
welder, after the browsing screen was accessed by pressing the 

 

cursor keys simultaneously; to quit the browsing screen, press STOP/
RESET. Or he enters the start and the end of the desired date range or 
report range, of which the reports should be downloaded. Whatever the 
selected option, the input screen that appears adapts to the input cur-
rently needed to enter the desired restriction of reports to download. All 
inputs have to be confirmed by pressing the START/SET key.

After successful download, the machine displays a message telling the 
welder that the process was o.k.

5.2 

Showing Reports in Memory, Printing Pipe Label Tags

Using the ViewWeld feature (see section 4.8), it is possible to display 
on the screen a certain welding report saved to memory and to print a 
label tag of that welding from the ViewWeld screen.

Printing label tags is possible only when the tag printer is connected to the 
USB A port of the machine. If this is not the case, an error is displayed. 
The printer can still be connected when the error message is showing; 
the machine recognizes this, the error disappears from the screen, and 
the download starts.

5.3 

Deleting Reports from Memory

To delete the reports stored in memory, use the appropriate option in the 
configuration menu (see sub-section 4.2). Upon touching this button, a 
safety warning asking if you really want to delete them appears on the 
screen and has to be confirmed to effectively delete the reports currently 
in memory.

6 System 

Data

6.1 

Setting the Date and the Time of Day

When the “Date/Time” sub-menu was selected in the configuration 
menu (see sub-section 4.2), the screen shows what is reproduced in 
Display 22.

The time of day and the date can be set using the keypad on the front 
panel.

Display 21

* Select File Type *
>DataWork File

PDF Abstract
PDF Ext'd Report

Display 22

** Set Time/Date ***

22.11.14       15:49

Содержание SP 63-M

Страница 1: ...bile Infrared Butt welding Machine SP 63 M Version October 2014 P O Box 1108 655 Andover St Lawrence MA 01843 Tel 800 343 3618 781 321 5409 Fax 800 787 6861 Website www asahi america com Email asahi a...

Страница 2: ...ning the Mechanical Structure of the Machine 17 4 7 Welding Process 18 4 7 1 Facing the Component Butts 18 4 7 2 Checking Alignment 19 4 7 3 Inserting the Heating Element with or without Preheating 20...

Страница 3: ...r as a power supply without this safety element may cause severe machine damage If the machine is operated through a power supply without a grounding conductor this will void any and all warranty unde...

Страница 4: ...astics agru SP 63 mobile safely Every person who operates the machine will have to conform to the instructions of this manual The machine has been developed and checked with respect to welding AGRU pi...

Страница 5: ...welding process it must not be operated if unobserved and sufficient distance to combustible materials in its surroundings has to be ensured Do not touch the heating plate or the plate housing The saf...

Страница 6: ...as to make sure that only one person is present in the zone where the machine is operating 2 5 Worksite Description The conditions have to fully ensure that the machine cannot slide As well the segmen...

Страница 7: ...eeded exeptionally contact agru Kunststofftechnik It is also part of the intended use to conform to the instructions provided in the User s Manual Important The manufacturer can in no circumstances be...

Страница 8: ...ntrol Unit with Control Panel Support Bracket f r Facing Tool and Heating Element Thumb Screws for Locking the Outer Clamp analogous on the other carriage Connector for Power Cord to Label Tag Printer...

Страница 9: ...376 x 348 mm 21 11 16 x 14 25 32 x 13 11 16 260 x 350 x 294 mm 10 1 4 x 13 13 16 x 11 7 16 800 x 600 x 608 mm 31 1 2 x 23 5 8 x 23 15 16 14 2 kg 31 2 U S lbs 6 6 kg 14 5 U S lbs on base plate 30 kg 66...

Страница 10: ...of up to 500 C 930 F not to be hazardous When starting the machine up remove the transport locks before applying power to the machine if it was transported before start up and the locks were engaged...

Страница 11: ...e clean or must be cleaned before welding starts To insert or remove the inserts do not use heavy tools hammer wrench They may damage the inserts and the magnets Important The surfaces of the heating...

Страница 12: ...this display it is possible to start the welding process and to customize the configuration of the machine Zeroing the Position of the Movable Carriage Wichtig Without proper zeroing of the reference...

Страница 13: ...change the machine settings in the configuration menu press the MENU key Info Other functionalities that are called when the default screen is showing are explained below in this booklet including how...

Страница 14: ...g In the default screen see Display 3 it is possible to change the weld specific parameters for the joint to be welded To do so press the STOP RESET key The screen that allows selecting the material o...

Страница 15: ...iameter for this material has to be entered in the same way After having confirmed this input by OK once more another screen allows entering the wall thickness for this material and size After the wal...

Страница 16: ...ption it is possible to delete all addi tional user defined parameters Here too deleting is possible only after cofirming it in a safety message After deleting them only the default materials with whi...

Страница 17: ...of the machine the facing tool and the heating element have to be inserted by their bars meant to hold them into the respective opening of the tabletop support see draw ing to the right 4 7 Welding Pr...

Страница 18: ...Info If the key is released before the carriage moves apart the facing tool pauses to allow for removing shavings when holding down the cursor key again the machine resumes facing When the machine ha...

Страница 19: ...tells the welder to insert the heating element in between the components see Display 12 As soon as it is properly position the machine recognizes this automatically and asks the welder to move the mo...

Страница 20: ...he change over stage or that no error occurred at all This info message can be acknowledged by pressing the START SET key 5 12 Using ViewWeld to Manage Logged Welding Reports and Print Tags The ViewWe...

Страница 21: ...Error of Memory If empty error despite no report in memory download was started if full error there are no more unused slots for reports and memory control is enabled No Function Available A control k...

Страница 22: ...nt meaning of the binary figure can be seen with the help of the code table below For instance if a label tag says 00010000 an error in the pre heating stage of the process occurred For that bit is se...

Страница 23: ...reports should be downloaded Whatever the selected option the input screen that appears adapts to the input cur rently needed to enter the desired restriction of reports to download All inputs have t...

Страница 24: ...request are shipped with the most recent software version Info At the date of shipment the service and maintenance interval is set to 18 months or 5000 welding operations different in some markets whi...

Страница 25: ...44 Central 800 442 7244 West 800 282 7244 Fax 800 787 6861 www asahi america com asahi asahi america com P O Box 1108 655 Andover St Lawrence MA 01843 Tel 800 343 3618 781 321 5409 Fax 800 787 6861 We...