background image

7

Anaconda  

USER MANUAL

To accommodate individual user needs, the Anaconda has a variety of digitally controlled options, 

such as:

•  Display brightness
• Palette color selection
• User-Controlled, Manual Non-Uniformity Correction/ Flat-Field Correction (UCMNUC/ FFC) 
•  Imaging enhancements
• Custom settings

Anaconda series clip-ons are based on FLIR Tau 2 cameras that offer improved overall image 

quality in a wide range of dynamic thermal environments. The Anaconda includes special, user-

adjustable imaging tools that include:

• Active Contrast Enhancement (ACE)

 – a digital “Contrast” correction that allows for smart  

scene optimization based on dynamic adjustments, where a variety of contrast levels occur 

depending on relative scene temperature.

• Second Generation Digital Detail Enhancement (DDE)

 – a “Sharpness” correction that digitally 

enhances the picture, significantly sharpens edges, and further reduces image noise.

• Smart Scene Optimization (SSO)

 – a fine-tuning computational correction that significantly 

improves overall visual acuity for targets that have thermal signatures similar to the surrounding 

background.

• 

Automatic Gain Control (AGC)

 – a “Gain“ correction that used to automatically adjust the gain to 

an appropriate range, the weaker the image signal, the stronger the gain.

• User-Controlled Manual Non-Uniformity Correction/ Flat-Field Correction (UCMNUC/ FFC). 

There is a mechanical shutter between the camera sensor and the lens. This shutter is used to 

perform a non-uniformity correction (NUC), also known as flat-field correction (FFC). During FFC, 

the shutter presents a uniform temperature source to each detector element in the array. While 

imaging the flat-field source, the camera updates the offset correction coefficients, resulting 

in a more uniform image after the process is complete. All Anaconda models allow for user to 

manually trigger or interrupt scheduled UCMNUC/ FFC function.  

• Silent Shutterless NUC™ (SSN)

 – In addition to User-Controlled Manual NUC/ FFC, all Anaconda 

models employ a digital, supplemental, non-mechanical flat-field correction that extends 

periods between mechanical shutter events and further reduces image noise. SSN is an always 

ON enhancement. 

Information on the current operating state (battery status, active function, etc.) is continuously 

shown, making field operation of the Anaconda simple and convenient.
Manufactured for exceptional durability, the Anaconda has a lightweight and robust aluminum 

body. A side Picatinny/Weaver rail allows the user to install an optional HD Video Recorder, WiFi 

Attachment, Extended Battery Pack, or other equipment.
A standard NTSC/PAL video input/output connector enables an external video display (monitor, 

TV) or video recorder to be connected to the Anaconda. 
The Anaconda is powered by two CR123A (2×3V) batteries. An external 6VDC/600mA power 

source and USB power bank can also be connected to the Anaconda.
The quick-release mount of the Anaconda fits any Picatinny, MIL-STD-1913, or Weaver weapon rail. 

The mount’s lever-cam clamping device ensures easy, quick, and reliable mounting and removal.

Содержание ANACONDA Series

Страница 1: ...USER MANUAL ANACONDA THERMAL IMAGING CLIP ON SYSTEM...

Страница 2: ...on Regulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export...

Страница 3: ...Key Features 11 2 OPERATING INSTRUCTIONS 12 2 1 Installation and Mounting 12 2 2 Controls and Display Indicators 18 2 3 Operating Procedures 26 3 MAINTENANCE INSTRUCTIONS 29 3 1 Operator Troubleshoot...

Страница 4: ...G THE FIREARM verify that your installation provides sufficient space between the eyepiece and the scope to account for the recoil generated by your rifle NOTE Give special attention to this warning w...

Страница 5: ...g the batteries Thoroughly clean and dry all items before placing them into the storage case To avoid deformation or damage remove the light suppressor from the Anaconda before placing the equipment i...

Страница 6: ...ing on the selected image palette NOTE It is important that the Anaconda sensor receive sufficient thermal contrast between the target and background area or between the different parts of a target Fo...

Страница 7: ...shutter is used to perform a non uniformity correction NUC also known as flat field correction FFC During FFC the shutter presents a uniform temperature source to each detector element in the array W...

Страница 8: ...1 2 SYSTEM DESCRIPTION 1 2 3 4 5 7 8 12 11 UNIVERSAL CONNECTOR S620 MICRO USB CONNECTOR 13 14 10 9 6 TABLE 1 1 SYSTEM DESCRIPTION ITEM DESCRIPTION ITEM DESCRIPTION 1 Body 8 Battery Cap 2 Mount 9 Unive...

Страница 9: ...ITY 1 Anaconda Thermal Imaging Clip On system 1 2 Objective Lens Cap 1 3 Output Lens Cap 1 4 Mount 1 5 Battery Cassette 2 6 CR123A Lithium Battery 2 7 Wireless Remote Control 1 8 Picatinny Adapter for...

Страница 10: ...lenses of specified day scopes Includes a clamp with inserts that will fit 38 and 42 mm diameters 6106SM21 Scope Mounting System 3 for Anaconda TC50 640 only A mounting system used to install the Ana...

Страница 11: ...tness User Controlled Manual Non Uniformity Correction Flat Field Correction UCMNUC FFC Current operational state information display battery status active profile palette setting Wireless remote cont...

Страница 12: ...into the cassette Align the polarity symbols on the batteries with the polarity symbols on the cassette 4 Reinsert the cassette with installed batteries 5 Replace the battery cap 2 1 2 INSTALLING THE...

Страница 13: ...athead socket cap screws D FIGURE 2 2 THE ANACONDA FULLY ASSEMBLED WITH THE MOUNT A B E C D Figure 2 3 shows the Anaconda mounted in front of a day scope To install the Anaconda on a Picatinny Weaver...

Страница 14: ...2 To tighten loosen the clamping device B push the cam C towards the arrow which will cause the nut A to slide out of its hole Turn the nut A CW CCW respectively in one two increments see note below B...

Страница 15: ...r Figure 2 6 shows the Anaconda TC50 640 installed on the lens of a day scope Install the Anaconda on the lens of a day scope as follows refer to Figure 2 7 1 Using a 2 5 mm Allen key unscrew the M4 8...

Страница 16: ...tool cut the inside face of the ring E Figure 2 7 The value of cuts in millimeters should be equal to the value of the turning angle in angular degrees divided by 360 5 Screw the ring E into the SMS...

Страница 17: ...the AGM HD Video Recorder WiFi Attachment or the Extended Battery Pack 2 1 8 CONNECTING AN ADDITIONAL EQUIPMENT CAUTION Turn off the Anaconda before removing the batteries or connecting disconnecting...

Страница 18: ...ector 2 2 CONTROLS AND DISPLAY INDICATIONS 2 2 1 CONTROLS CAUTION DO NOT force the equipment controls past their stopping points The Anaconda controls are shown in Figures 2 13 and 2 14 and are define...

Страница 19: ...ntrol button to deactivate the device Battery Status Indicator a battery icon in the top right hand part of the display The color fill green yellow red bar in the battery icon indicates the current po...

Страница 20: ...progressively push button 2 Reticle on off Pushing and holding button 2 to reticle ON OFF 4 Reticle Color Control To change the reticle color push button 4 There are four colors available of the reti...

Страница 21: ...when specified on the menu screen with symbols After a menu item is selected push the OK button to make the selected setting activate the selected function Select the EXIT item and then push the OK b...

Страница 22: ...ckly and properly interpret the thermal image being displayed Reticle Menu The RETICLE menu Figure 2 19 allows the user to select from a choice of reticle patterns Dot Type Line Dot Crosshair Center D...

Страница 23: ...buttons to adjust for windage Moving the reticle in the positive direction to the right will move the POI to the left Moving the reticle in the negative direction to the left will move the POI to the...

Страница 24: ...use hotter objects to get more contrast while higher values will cause colder objects get more contrast SHARPNESS Second Generation Digital Detail Enhancement DDE a sharpness correction that digitally...

Страница 25: ...2 25 GAIN CORRECTION GAIN 0 GAIN 35 AGC SPEED parameter that allows user to control the refresh rate of Automatic Gain Control AGC The adjustment range is from 0 to 128 with a default value of 12 Sett...

Страница 26: ...before you place the equipment on the firearm Always verify that the chamber is empty especially if you stop the procedure and resume later Safe handling rules should be followed at all times CAUTION...

Страница 27: ...by one level at a time until you reach your desired brightness level B Use UCMNUC FFC User Controlled Manual Non Uniformity Correction Flat Field Correction function to improve image quality As the ca...

Страница 28: ...once to turn it off press the button again 2 To operate the device in short time activation mode see note below press and hold the remote control button down for 1 5 seconds Release the remote control...

Страница 29: ...CAUSE TEST INSPECTION CORRECTIVE ACTION The Anaconda fails to activate Batteries are missing or improperly installed Insert batteries or install correctly Batteries are dead Replace the batteries Batt...

Страница 30: ...2 MAINTENANCE 3 2 1 GENERAL The Anaconda operator maintenance consists of operational tests inspections for unit serviceability cleaning and mounting procedures corrective actions troubleshooting and...

Страница 31: ...3 BORE SIGHTING Perform the Anaconda bore sighting When the Anaconda is mounted to a new weapon for the first time After repair of the Anaconda weapon As the need arises in case of systematic inaccura...

Страница 32: ...tible with or of inferior quality to the product as well as failure to maintain the environmental conditions specified by the manufacturer This warranty is extended only to the original purchaser Any...

Страница 33: ...improper postage or merchandise that becomes lost or damaged during shipment When sending product back please clearly write the RMA on the outside of the shipping box Please include a letter that ind...

Страница 34: ...Color 1 Color 2 Ice Fire Rain and OEM User adjustable Image Enhancement Tools Active Contrast Enhancement ACE CONTRAST Second Generation Digital Detail Enhancement DDE SHARPNESS Smart Scene Optimizati...

Страница 35: ...ries 3 7V or four CR123 type rechargeable batteries with voltage 3 7V max or four standard CR123A 3V Lithium batteries operational time up to 8 hr External Power Supply Power bank 5V via Micro USB por...

Страница 36: ...ERTURE OF DAY SCOPE LENS MM EXAMPLE OF THE SCOPES Scope Mounting System 1 53 39 5 43 52 4 25 4 20 24 Leupold 1 5 5x20 PR 30 0 Leupold 1 5 5x20 MR T M2 Zeiss 1 1 4x24T Scope Mounting System 2 61 44 49...

Страница 37: ...emoved in order to replace authorized parts The PART NO column indicates the primary number used by the manufacturer to identify an item which controls the design and characteristics of that item by m...

Страница 38: ...AGMANF25OLA F40 Output Lens Assembly AGMANF40OLA 9 Operation Switch AGMTIDOPSW 10 Side Picatinny Weaver Rail AGMTIDSPR 11 Battery Cassette AGMTIDBTCS 12 Wireless Remote Control AGMTIDWRC 13 Picatinny...

Страница 39: ......

Страница 40: ...ain Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 Fax 1 480 393 4882 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 44...