40
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
1
What's New
Changed
Commands
Command
Differences From InfiniiVision 3000 X-Series Oscilloscopes
:ACQuire:MODE (see
page 231
)
The ETIMe mode is available with the 1 GHz or 1.5 GHz
bandwidth models.
:CALibrate:OUTPut (see
page 257
)
The TRIG OUT signal can be a trigger output, mask test failure,
or waveform generator sync pulse from either WaveGen1 or
WaveGen2.
:DEMO:FUNCtion (see
page 294
)
The USB and NMONotonic functions are now available with the
DSOXEDK educator's kit license.
:DISPlay:VECTors (see
page 322
)
The OFF parmeter is available with the 1 GHz or 1.5 GHz
bandwidth models.
:FUNCtion<m>:OPERation
(see
page 358
)
The AVERage parameter is available for the Averaged Value
math function.
:MARKer:MODE (see
page 394
)
You can now select the BINary or HEX marker modes.
:MEASure:SHOW (see
page 457
)
This now has an OFF state when markers are not in
measurement mode.
:MEASure:WINDow (see
page 481
)
This now has a GATE option for gated measurements between
the X1 and X2 cursors.
:RECall:ARBitrary:[STARt] (see
page 615
)
There is now an option to specify which waveform generator to
recall the arbitrary waveform into.
:SAVE:ARBitrary:[STARt] (see
page 624
)
There is now an option to specify which waveform generator to
save the arbitrary waveform from.
:SAVE:WAVeform:FORMat
(see
page 639
)
The ALB Agilent module binary format is not supported by the
4000 X-Series oscilloscopes.
:SBUS<n>:MODE (see
page 649
)
The USB mode is now available with the DSOX4USBFL (USB 2.0
Full/Low Speed) or DSOX4USBH (USB 2.0 High Speed) serial
decode and triggering licenses.
:TRIGger[:EDGE]:SOURce (see
page 965
)
You can now trigger on the WGEN1 or WGEN2 outputs or, when
FM or FSK modulation is used, you can trigger on the WMOD
modulating signal output.
:TRIGger:MODE (see
page 944
)
The USB mode has been superseded by commands that are
available with the DSOX4USBFL (USB 2.0 Full/Low Speed) or
DSOX4USBH (USB 2.0 High Speed) serial decode and triggering
licenses. See
“:SBUS<n>:USB Commands"
on page 792.
:WGEN<w> Commands (see
page 1055
)
With the built-in waveform generator's (with Option WGN
license) two outputs, you can use :WGEN1 and :WGEN2 to
specify which output you are controlling. :WGEN is the same as
:WGEN1. Maximum waveform generator amplitudes and offsets
are also different.
:WMEMory<r> Commands
(see
page 1099
)
<r> is now from 1 to 4 with four reference waveform memories.
Содержание InfiniiVision 4000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Страница 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Страница 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Страница 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Страница 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Страница 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Страница 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Страница 308: ...308 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 13 DIGital d Commands ...
Страница 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Страница 336: ...336 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 16 EXTernal Trigger Commands ...
Страница 368: ...368 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 17 FUNCtion m Commands ...
Страница 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Страница 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Страница 506: ...506 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 22 MEASure Power Commands ...
Страница 542: ...542 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 24 POD Commands POD1 DISP 0 THR 1 40E 00 ...
Страница 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Страница 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Страница 1206: ...1206 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 39 Synchronizing Acquisitions ...
Страница 1336: ...1336 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 41 Programming Examples ...
Страница 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...