76
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
4
Commands Quick Reference
n/a
:TER? (see
page 225
)
{0 | 1}
:VIEW <source> (see
page 226
)
n/a
<source> ::= {CHANnel<n> |
FUNCtion<m> | MATH<m> | SBUS{1 |
2} | WMEMory<r>} for DSO models
<source> ::= {CHANnel<n> |
DIGital<d> | POD{1 | 2} | BUS{1 |
2} | FUNCtion<m> | MATH<m> |
SBUS{1 | 2} | WMEMory<r>} for MSO
models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<m> ::= 1-4 in NR1 format
<r> ::= 1 to (# ref waveforms) in
NR1 format
Table 3
Root (:) Commands Summary (continued)
Command
Query
Options and Query Returns
Table 4
:ACQuire Commands Summary
Command
Query
Options and Query Returns
:ACQuire:COMPlete
<complete> (see
page 229
)
:ACQuire:COMPlete?
(see
page 229
)
<complete> ::= 100; an integer in
NR1 format
:ACQuire:COUNt
<count> (see
page 230
)
:ACQuire:COUNt? (see
page 230
)
<count> ::= an integer from 2 to
65536 in NR1 format
:ACQuire:MODE <mode>
(see
page 231
)
:ACQuire:MODE? (see
page 231
)
<mode> ::= {RTIMe | ETIMe |
SEGMented}
n/a
:ACQuire:POINts? (see
page 232
)
<# points> ::= an integer in NR1
format
:ACQuire:RSIGnal
<ref_signal_mode>
(see
page 233
)
:ACQuire:RSIGnal?
(see
page 233
)
<ref_signal_mode> ::= {OFF | OUT
| IN}
:ACQuire:SEGMented:AN
ALyze (see
page 234
)
n/a
n/a (with Option SGM)
:ACQuire:SEGMented:CO
UNt <count> (see
page 235
)
:ACQuire:SEGMented:CO
UNt? (see
page 235
)
<count> ::= an integer from 2 to
1000 in NR1 format (with Option
SGM)
:ACQuire:SEGMented:IN
Dex <index> (see
page 236
)
:ACQuire:SEGMented:IN
Dex? (see
page 236
)
<index> ::= an integer from 1 to
1000 in NR1 format (with Option
SGM)
Содержание InfiniiVision 4000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Страница 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Страница 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Страница 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Страница 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Страница 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Страница 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Страница 308: ...308 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 13 DIGital d Commands ...
Страница 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Страница 336: ...336 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 16 EXTernal Trigger Commands ...
Страница 368: ...368 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 17 FUNCtion m Commands ...
Страница 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Страница 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Страница 506: ...506 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 22 MEASure Power Commands ...
Страница 542: ...542 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 24 POD Commands POD1 DISP 0 THR 1 40E 00 ...
Страница 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Страница 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Страница 1206: ...1206 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 39 Synchronizing Acquisitions ...
Страница 1336: ...1336 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 41 Programming Examples ...
Страница 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...